6.8 Connection of 2.4 GHz Portable Stations — KX-TDA30
6.8.7
Connecting a Cell Station to the Hybrid IP-PBX
Refer to the following example to connect a CS to the Hybrid IP-PBX.
A Super Hybrid Port,
or DLC4/DLC8 card (RJ45)
Signal Name
D2
D1
A Super Hybrid Port,
or DLC4/DLC8 card (RJ11)
Signal Name
D1
D2
Accessory and User-supplied Items for the CS
Accessory (included): Screws × 2, Washers × 2
User-supplied (not included): RJ45 connector or RJ11 connector
Note
For details about DLC4 card or DLC8 card, refer to "6.4.1 DLC4 Card" or "6.4.3 DLC8
Card".
362
Installation Manual
Super Hybrid Port
Pin No.
1
2
3
4
5
6
7
8
Pin No.
1
2
3
4
Cable
Maximum Distance
ø 0.4 mm:
Under 222 m
ø 0.5 mm:
Under 347 m
ø 0.6 mm:
Under 500 m
CAT 5:
Under 347 m
Pin No.
Pin No.
CS (RJ11)
Signal Name
1
D1
2
3
4
D2
CS (RJ11)
Signal Name
1
D1
2
3
4
D2