The dosing pump's hose is replaced without removing the rotor.
Remove the empty suction and pressure hoses from the hose
fastener. To do so, loosen the blue clamp screws.
Remove transparent cover 1 from the pump.
Remove transparent cover 2 from the rotor.
Turn rotor 3 such that the flat side faces left and is vertical.
Pull hose fastener 4 from its bracket and lift on the left side.
Turn rotor 3 clockwise and remove the cable while lifting on it
until it is completely free.
To install, perform in the opposite order.
Either the hose can be replaced alone, or the hose and hose fastener
can be replaced jointly.
It is recommended to replace hose and hose fastener jointly.
Art. no.
Designation
127313
Replacement hose set
1.5 l/h (hose with hose
fastener)
127356
Replacement hose set
3.0 l/h (hose with hose
fastener)
127303
Pump hose 1.5 l/h (hose
without hose fastener)
127353
Pump hose 3,0 l/h (hose
without hose fastener)
NOTE
If only the hose is being replaced, then the following
absolutely must be observed during installation
 The hose sits securely in the grommets.
 Under no circumstances may the hose be twisted
when installed.
 Ensure the hose clip sits securely.
74
Application
Chlorine and pH for pool sizes up to ca.
100 m
3
Chlorine and pH for pool sizes of
approx.100 m
to ca. 200 m
and for
3
3
dosing Bayrosoft
.
®
Chlorine and pH for pool sizes up to ca.
100 m
3
Chlorine and pH for pool sizes of
approx.100 m
to ca. 200 m
and for
3
3
dosing Bayrosoft
.
®
39

Winter breaks

No special measures are necessary for short breaks in usage (e.g.
several days).
For longer operational breaks of multiple weeks, such as the winter
months, the following work must be performed:
Remove suction lances from the canisters and rinse them with
water.
Close packages, store them in a cool and dry location protected
from UV radiation.
Rinse hose pumps with water. To do so, run the pumps in
manual mode.
Remove the unit from the power supply.
Remove the dosing hoses from the pumps.
Turn off measuring water supply.
Empty the measuring water circuit and hose pumps completely.
Remove glass electrodes (pH and Rx electrode) from the
measuring chamber and seal screw apertures.
Store electrodes in the original containers with the solution
contained (KCl).
Store electrodes in a location from frost.
After winter has passed, follow the instructions for first start-up to
render the system operational again.
In doing so, be sure to inspect all components for their capacity to
function.
All dismounted parts (electrodes, dosage hoses) must be remounted
at their intended locations.
Check the settings in PoolManager
for first start-up and calibrate the electrodes as described.
40

Decommissioning

If disposing of the device after its service life, be sure to rinse it
thoroughly and drain all water. This device has been manufactured in
compliance with the ROHS directive and the German laws on
electronic equipment disposal. Do not dispose of this equipment along
with regular waste.
Deliver the device to a suitable collection point. Refer to the rules and
laws of your area.
®
. In doing so, follow the procedure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poolmanager brominePoolmanager oxygenPoolmanager pro

Table of Contents