Dosing pumps

42.1

Peristaltic pumps

The standard PoolManager
®
dosing pumps are so-called peristaltic
pumps (hose pumps). Rollers on the rotor continuously squeeze the
dosage hose, thereby providing for the dosing of maintenance
products.
The pump's dosage hose is replaceable. The pump's dosing output
can be adjusted via various hose diameters.
The following table shows the standard dosing outputs on
PoolManager
®
dosing pumps.
Function
pH (pH minus / pH plus)
Cl (sodium hypochlorite)
O2 (Bayrosoft
)
®
The pumps used are run with a 230 V~ power supply. PoolManager
control system periodically turns the dosing pumps on and off within a
fixed dosage cycle (typically 60s) in order to realise the dosing output
calculated. A higher dosing output will lead to longer turn-on times.
42.1.1

Electrical connection

Required user qualification:
ELECTRICAL SPECIALIST
The electrical connection for eco mode may only be
performed by an ELECTRICAL SPECIALIST as
defined in the chapter User qualification.
The following figure shows the internal wiring of the three dosing
outputs for disinfection, pH-, and pH+. All connections shown are run
internally as conductor paths.
1
Fuse 2 AT for the 230 V~ Phase L
for supplying dosing outlets
The following terminal blocks are allocated to the dosing outputs:
Dosing output
Terminal block Function
Disinfection
20
pH- (pH minus)
27
pH+ (pH plus)
22
76
Standard dosing hos
(dosing output)
1.5 l/h
1.5 l/h
3 l/h
®
D
On / off switch
On / off switch
On / off switch
Each terminal block is set up as follows:
Terminal
Function
b
Working contact
a
Centre contact
L D
Supply phase 230 VAC for dosing outputs.
Can be bridged to the centre contact if needed in
order to control 230 VAC devices.
The following figure schematically shows the connection of a standard
dosing pump for 230 V~. The pump is connected to the disinfection
dosing output. For pH- and pH+, connection is correspondingly on
terminal blocks [21] and [22], respectively.
1
Standard dosing pump 230 V~
(peristaltic pump)
2
Wire bridge in the terminal box from phase L
centre relay contact a
INFO
Connection of neutral conductor N and PE
A dosing pump's neutral conductor N and protective
earth PE can be connected to the N
blocks as shown in the figure.
Wire bridges in the terminal box from phase L
centre relay contact a
to
D
and PE terminal
D
to the dosage outputs'