9
8.5.1

Calling up quick info

To call up quick info, the normal address for remote access (IP
address or URL) is attached along with the following suffix:
/cgi-bin/webgui.fcgi?infoframe=0
Thus, a complete URL would be, for example
http://myPoolManager.dtdns.net/cgi-bin/webgui.fcgi?infoframe=0
This URL is relatively complicated, but it can easily be stored in the
browser as a favourite.
TIP
Multiple devices at a glance
If you are a specialist in charge of multiple
PoolManager
units, you can have the quick info of all
®
relevant devices displayed jointly on one webpage. To
do so, you could e.g. design a simple HTML webpage
(frame page) locally on your PC which shows clearly
arranged the quick infos of all relevant controllers.
This means you'll have the most important information
from all controllers in one place.
If, for example, there is a controller showing an alarm
(red text), then you can directly access that controller
with one click.
9
Display and operation - Graphical user
interface
Display and operation are realised on a large TFT colour display with
touchscreen. The function shown can be executed with the simple tap
of a finger on the corresponding area on the screen. Each tap on the
touchscreen is confirmed with a signal tone.
To the right of the display, there are 5 "hotkeys" for important standard
functions. The hotkey functions are also selected with a simple finger
tap and confirmed with a signal tone.
Menu (main menu)
Direct jump to main menu (icon menu)
Esc (escape)
Back to previous menu level
Home (home view)
Direct jump to home view
Help
Display help text for the current menu
Mode (mode menu)
Direct jump into mode menu for turning on or off
various functions quickly and easily. When main-menu is
entered pressing the menu-hotkey for a second time
activates/deactivates the background image in transparent
style.
14
9.1
Important menus
9.1.1
Home view
Home view is the standard view that can usually be seen on the
screen and provides an overview of all important data and operating
statuses. Home view can be called up at any time using the Home
hotkey.
1
Measured value display with additional
graphic measured value scale
2
Operating status and dosage status
3
Alarms
4
Add-on functions
The areas 1, 2, and 3 in one column mutually relate to a measurement
or control module, such as pH, redox, chlorine, or temperature.
1 Measured value display with graphic measured value scale
Colour of measured value display:
green
Normal operation, everything OK
yellow
Dosage blocked (missing flow signal
and/or start delay)
red
Alarm, dosage blocked!
1
Current measured value (arrow)
2
Setpoint (numeral value and mark)
3
Lower alarm threshold
4
Upper alarm threshold
2 Operating status and dosage status
1
Operating mode or operating status
2
LED indicates whether the dosing pump
is currently running
3
Dosing direction
D- Decrease the measured value
D+ Increase the measured value
4
Current dosing rate as %
Example: 10 % means that the dosing
pump is turned on for 10 % of the
available time. It will then run, for
example, for 6s if the dosing cycle is set
to 60s.
5
Fill level in the corresponding canister:
Sufficient volume available
Limited residual volume available
The canister is empty and has to
be replaced