Maintenance

IMPORTANT NOTICE
Use only replacement parts and sensors from the
manufacturer. Otherwise, the warranty will be
forfeited.
IMPORTANT NOTICE
Electrodes are wear and tear parts and therefore not
included in the warranty.
Some PoolManager
parts are subject to abrasion due to chemical
®
and mechanical strain. Therefore, regular control is necessary for safe,
long-term operation. Regular precautionary maintenance of the system
protects against unplanned operating interruptions.
38.1

Monthly maintenance

Visual inspection of all dosage lines and hoses
Check filter screen, clean as needed
Check water values using the test kit provided, adjust electrode
settings and calibration as necessary
38.2

Quarterly maintenance

Visual inspection of all dosage lines and hoses
Check screen, clean as needed
Check water values using the test kit provided, adjust settings and
calibration as necessary
Calibration of pH and redox electrodes using the buffer solutions
provided
Calibration of chlorine electrodes (PoolManager
Maintenance of injection points
38.3

Annual maintenance

Visual inspection of all dosage lines and hoses
Check screen, clean as needed
Check water values using the test kit provided, adjust settings and
calibration as necessary
Replace pH and redox electrodes and calibrate using fresh buffer
solutions
Replace the chlorine measuring cell's glass electrode and
calibrate the chlorine measurement cell (PoolManager
Maintenance of injection points
Replace the hoses on the dosing pumps
PoolManager
PRO only
®
The lifespan of the gold electrodes in the chlorine
measuring cell is approx. 5 years. Depending on the
degree of utilisation, it may be necessary to replace a
gold electrode earlier.
NOTE
Do not use buffer solutions that are more than 12
months old.
NOTE
The lifespan on glass electrodes depends on the
operating conditions and the water's properties. It is
normally approx. 12 months; storage time is applied
at 50 %.
38.4
Clean the unit's surface as needed using a towel that is soft and free
of fuzz. Only use a small amount of water, if necessary.
38.5
PRO only)
®
PRO only)
®
NOTE
Maintenance frequency is only partially dependent
upon utilisation intensity. Chemical strain, for example,
on plastic parts begins immediately upon first contact
with the medium and is not dependent upon the type of
utilisation.

Cleaning

IMPORTANT NOTICE
Do not use aggressive cleaning products.

Dosing pump hose replacement

NOTE
Never grease hoses!
NOTE
Only original replacement pump hoses may be used!
NOTE
Hose of pump are wear and tear parts and therefore
not included in the warranty.
HAZARD!
Hazard due to chemicals
Corrosive product residue may come out of the pump
hose when pulled off.
Potential consequence: Grave health hazard
(chemical burns) and material damage
Always be sure to empty pump hoses and feed
lines first.
When necessary, use protective eye wear and
gloves and protect the surrounding area from
escaping product residue using a towel.
HAZARD!
Hazard due to rotating parts
The dosing pump's rotor may start immediately.
Potential consequence: Crushing of fingers!
Ensure that the dosing pump remains separated
from the operating voltage (unplug) when replacing a
hose!
73