12
1
Dosing rate in %
2
Measured pH value
3
Configured setpoint pH 7.20
4
pH measured value is higher than setpoint 
pH minus dosing
5
pH measured value is lower than setpoint 
pH plus dosing
6
Dosing output for various proportional ranges
12.4.10 Recommended settings
(PoolManager
Cl / Br / O2)
®
The following table provides information on the recommended
parameter settings for pH and redox control.
Recommended parameter settings
Parameter
pH
Setpoint
Ideal range
pH 7.0 ... 7.4
Lower alarm
approx. setpoint - 0.4 pH
threshold
Upper alarm
approx. setpoint + 0.4 pH
threshold
Proportional
approx. 1.50 pH
range
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Proportional range
Minimum
approx. 4.0 %
dosing rate
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Minimum dosing rate
Intelligent
The standard setting (60 min) delivers good results in most
dosing
applications and should only be changed in exceptional
monitoring
cases; see section
Intelligent dosing monitoring
Deadzone
0.00 pH for mono-directional
control,
0.10 pH for bi-directional
control
Dosing cycle
The standard setting (60s) delivers good results in most
applications.
For very small pools, e.g. whirlpools, it may be sensible to
reduce to 30s.
Dosing
Depending on
direction
water composition:
D- (pH-reducing),
D+ (pH-increasing) or bi-
directional (D+/D-)
32
Redox (mV)
The right redox setpoint has
to be determined individually
for each pool; please refer to
the section
Determining the
redox (mV) setpoint
approx. setpoint - 50 mV
approx. setpoint + 50 mV
approx. 150 mV
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Proportional range
approx. 4.0 %
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Minimum dosing rate
0mV
D+
(Increase in redox value by
dosing chlorine or bromine)
12.4.11 Recommended settings
(PoolManager
PRO)
®
The following table provides information on the recommended
parameter settings for pH and chlorine / bromine control.
Recommended parameter settings
Parameter
pH
Setpoint
Ideal range
pH 7.0 ... 7.4
Lower alarm
approx. setpoint - 0.4 pH
threshold
Upper alarm
approx. setpoint + 0.4 pH
threshold
Proportional
approx. 1.50 pH
range
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Proportional range
Minimum
approx. 4.0 %
dosing rate
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Minimum dosing rate
Intelligent
The standard setting (60 min) delivers good results in most
dosing
applications and should only be changed in exceptional
monitoring
cases; see section
Intelligent dosing monitoring
Deadzone
0.00 pH for mono-directional
control,
0.10 pH for bi-directional
control
Dosing cycle
The standard setting (60s) delivers good results in most
applications.
For very small pools, e.g. whirlpools, it may be sensible to
reduce to 30s.
Dosing
Depending on
direction
water composition:
D- (pH-reducing),
D+ (pH-increasing) or bi-
directional (D+/D-)
12.5
Configuration Wizard
12.5.1
Basics
Sensible configuration of the proportional range and the minimum
dosing output is largely dependent upon pool volume and dosing
pump output. In the end, what counts is the ratio between pool volume
and the pumps' dosing output.
The values used as the basis for the default settings are:
Assuming a typical pool volume of 40 m
standard dosing pump output 1.5 l/h
The assumed ratio between pool volume in [m³] and dosing output
in [l/h] is therefore 40 to 1.5, i.e. approx. 27.
For a larger pool volume in relation to the dosing pump output, the
control parameters generally have to be adjusted as follows:
Smaller proportional range (  higher dosing output)
Higher minimum dosing output
Accordingly, for a smaller pool volume in relation to the dosing pump
output the control parameters generally have to be adjusted as
follows:
Larger proportional range (  lower dosing output)
Lower minimum dosing output
Chlorine (Cl) / Bromine (Br)
Depending on application
region
approx. setpoint - 0.25 mg/l
approx. setpoint + 0.25 mg/l
approx. = 50 mg/l
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Proportional range
approx. 4.0 %
for 40 m³ pool and
dosing pumps 1.5 l/h,
see section
Minimum dosing rate
0 mg/l
D+
(Increase in chlorine /
bromine concentration)
3

Hide quick links: