Overview of user rights

User level ►
▼ Function
Standard access code
Complete menu navigation
"See everything - change nothing"
Setting uncritical parameters
Setting parameters critical to function
Setting parameters relevant to safety
Call-up Mode menu
1-point calibration
2-point calibration
Manual dosing
Acknowledge acoustic alarms
Acknowledge alarms
Acknowledge service messages
Master (level 4) - Special functions
Factory (level 5) - Special functions
Function permitted for the corresponding user level
Function not permitted for the corresponding user level, but can be released in the menu by system operator.
22.4

Enable remote access for various functions

In the menu Enable remote access for various functions, you can
define whether remote access is allowed or not for various functions. It
is possible to configure the following settings:
Allow remote access
Inactive
Remote access to the corresponding function is
blocked.
Local network
Remote access to the corresponding function is
released on the local network only, but not on
the Internet (Web).
Local network & Web
Remote access to the corresponding function is
released both on the local network and on the
Internet (Web).
Remote access can be released or blocked for the following functions:
Sub-menu Configure access rights for remote access
Allow remote access
Release of the Mode menu for remote access
to Mode menu
Depending on the system configuration, critical
functions might be turned on and off accidentally
during remote access to the Mode menu. That is
why the default setting blocks remote access to
the Mode menu.
Allow remote access
In general, calibration has to be performed on-
for calibration
site. That is why the default configuration blocks
remote access to calibration.
If needed, however, calibration can be released
for remote access if, for example, a mobile
device is going to be used on-site.
Allow remote access
In general, manual dosing has to be performed
for manual dosing
on-site. That is why the default setting blocks
remote access to the manual dosing. If needed,
however, calibration can be released for remote
access if, for example, a mobile device is going
to be used on-site.
Guest
Customer
(Level 0)
(Level 1)
-
1234
22.5
In the menu Adjust user levels for various functions, the required user
level for access to various functions can be adjusted as needed:
Sub-menu Adjust user level for various functions
User level
for 1-point calibration
User level
for manual dosing
User level
for Mode menu
Mode menu safety notice
Customer
Service
(Level 2)
(Level 3)
5678
8642

Adjust user levels for various functions

Required user level for
1-point calibration.
Potential settings:
 Customer (level 1)
 Customer (level 2)
Required user level for
manual dosing.
Potential settings:
 Customer (level 1)
 Customer (level 2)
Required user level for access to the Mode
menu.
Potential settings:
 Customer (level 0) ( no login!)
 Customer (level 1)
The safety advice which is usually displayed
when calling up the Mode menu, can be
deactivated here
Master
Factory
(Level 4)
(Level 5)
xxxx
xxxx