26.4

Electrical connection

Required user qualification:
ELECTRICAL SPECIALIST
Electrical connection of filter pump control may only be
performed by an ELECTRICAL SPECIALIST as
defined in the chapter User qualification.
IMPORTANT NOTICE!
Do not exceed the maximum currents
Do not exceed the maximum permissible electrical
currents for each individual relay switch output (max.
4 A) and for the sum of all relay switch outputs being
used in 230 V~ configuration (in sum, also max. 4 A)
Please also refer to the Chapter 230 V~ Power
supply.
The connection options already described for universal switch outputs
can be used for connecting a conventional filter pump; see Universal
switch outputs
connection options.
The connection of a variable filter pump is shown schematically in the
following figure.
1
Filter pump
2
Volt-free control input for on / off (optional)
3
Volt-free control inputs to select the operating mode
3a
Volt-free control input for normal mode
3b
Volt-free control input for eco mode
3c
Volt-free control input for increased mode
3d
Joint contact for all volt-free control inputs
4
External power supply for the filter pump 230 V~
(or 400 V~)
The following Allocation of inputs and outputs is required in the menu
for the connection schematic shown in this figure:
Function
Relay output 'Filter pump on/off'
Relay output 'normal mode'
Relay output 'eco mode'
Relay output 'increased mode'
27
Flockmatic
pump
®
27.1

Safety information

Required user qualification:
TRAINED SPECIALIST or
ELECTRICAL SPECIALIST
Connection, configuration, and start-up of Flockmatic
pump control may only be performed by a TRAINED
SPECIALIST or an ELECTRICAL SPECIALIST as
defined in the chapter User qualification.
27.2

Overview

PoolManager
offers the option of connecting and controlling a
®
Flockmatic
®
pump.
PoolManager
®
Flockmatic
®
control additionally offers the following
options:
Reducing Flockmatic
®
dosing rate
Blocking flock dosing in the event of missing flow
Multiple flexibly programmable timers
Optional level monitoring via a switch input
27.3
Menu Flockmatic
pump
®
The configuration menu for Flockmatic
following icon:
Flockmatic
®
pump
The following settings are available:
Menu Flockmatic
pump
®
Flockmatic
mode of operation
®
Selection of operating mode:
 Inactive (Flockmatic
control not used)
®
 Off (Flockmatic
used, but turned off)
®
 On
 Timer
Programmable timer
Programming timers.
Basic configuration
Basic settings for Flockmatic
control.
®
INFO
Allocation of a relay switch output
Flockmatic
control can only be activated if you have
®
allocated a relay switch output to it beforehand in the
Basic configuration menu.
Relay switch output
OUT 1 [26]
OUT 2 [27]
OUT 3 [30]
OUT 4 [31]
®