15.5

Show in the home view

Pos. Content
Notes
1
Current measured
0.0...50.0 °C (input T3: 0.0...75.0 °C)
value
Colour of measured value display:
green
yellow
red
2
Measured value scale Graphic display of current measured value
and alarm thresholds.
3a
LED symbol
The LED symbol is only displayed when the
add-on heating or solar heating functions are
being used.
It illuminates when the heating system is
currently heating.
3b
Status of heating
This status is only displayed when the add-on
and/or solar heating
heating or solar heating functions are being
used.
For details, please review the sections
Heating or Solar Heating.
4
Alarms
All active alarms are shown regarding
temperature measurement.
Alarms that are no longer active disappear
from the display, even if they have not yet
been acknowledged.
If there is no active alarm, "OK" appears.
15.6
Configuration temperature
Configuration of temperature measurement is performed in the menu:
Configuration Temperature
There, the following parameters can be configured:
Parameter
Setting range
Input for temperature
The input used for the main temperature display
display
on the controller can be selected.
Standard is Temp. input 1 [3]
Sub-menu Alarm limits
Lower alarm threshold
0.0...50.0 °C
T1 / T2 / T3
(T3 0.0...75.0 °C)
Upper alarm threshold
0.0...50.0 °C
T1 / T2 / T3
(T3 0.0...75.0 °C)
Sub-menu
Configuration of functions and sensor types for
Temperature sensor
T1 / T2 / T3
configuration
Normal operation,
everything OK
Flow signal missing
or start delay
Alarm
Standard setting,
default set Europe
10.0 °C
50.0 °C
15.7
Calibration
Calibration of temperature measurement is performed in the menu:
Calibration Temperature
Please perform calibration as follows:
1.
Select the temperature input to be calibrated
1-Point Calibration T1 / T2 / T3
2.
Measure the corresponding temperature (water, solar, air) for
the corresponding input on the thermometer
3.
Enter the temperature measured as the calibration value
4.
If the displayed measured value (Current value) is stable and is
no longer changing in a relevant manner, then confirm
calibration by pressing Next.
5.
Check the calibration results displayed and close calibration by
pressing Ready.
16
Manual dosing
16.1
Overview
For each module pH, chlorine (Cl) / bromine (Br), redox (mV), and O2,
there is the option of adding product to the swimming pool water via
manual dosing.
Manual dosing is restricted in time and will automatically end after the
selected dosing duration has passed. Furthermore, manual dosing can
be manually stopped at any time. During manual dosing, the dosing
pump runs continuously, i.e. at a dosing rate of 100%.
Manual dosing can be blocked by alarms; see section blocking via
alarms.
16.2
Menu manual dosing
Manual dosing can be started in the following menus
(depending on the controller model):
Manual Dosing pH
Manual Dosing Chlorine /Bromine
Manual Dosing mV (Chlorine) / Manual Dosing mV (Bromine)
Manual Dosing O2
41