25.3.2.1 External switch or push-button
Each switch output can be linked with an external switch or push-
button, which facilitates turning the function on or off manually.
The following settings can be configured:
Sub-menu External switch or push-button
External switch
Selection of an input to which the external switch is
connected
(IN 1 [6] / IN 2 [7] / IN 3 [8] / IN 4 [9] / none)
Type of external
On/off switch or push-button
switch
For on/off switch only
External switch on
Defines the operating mode when external
switch is turned on:
 Output ON
 Output AUTO,
(Operating mode controlled by PoolManager
External switch off
Defines the operating mode when external
switch is turned off:
 Output OFF
 Output AUTO,
(Operating mode controlled by PoolManager
For push-buttons only
External push-button
Start timer or
function
Output on/off
Timer function
Switch-on duration
switch-on time
(For the function Start timer)
25.3.3

Safety settings

HAZARD!
Hazard via remote access
Depending on the installation, hazards may be yielded
by universal switch outputs, particularly via remote
access.
Potential consequence: Death or the gravest
degree of injury, heavy material damage.
 Release of remote access to universal switch
outputs is expressly PROHIBITED for all
applications in which the safety of persons,
animals, and property is not completely guaranteed
at all times and under all circumstances; especially
for remote access.
 Safety is exclusively in the system operator's
sphere of responsibility.
 The controller manufacturer disclaims all liability.
HAZARD!
Hazard from erroneous operation in Mode menu
Switch outputs can be switched quickly and easily in
Mode menu. This also yields the hazard of an
erroneous operation (switching accidentally)
Potential consequence: Death or the gravest
degree of injury, heavy material damage.
 The display of universal switch outputs in Mode
menu is expressly PROHIBITED for all applications
in which the safety of persons, animals, and
property is not completely guaranteed at all times
and under all circumstances, especially in the case
of potential erroneous operation in Mode menu.
 Safety is exclusively in the system operator's
sphere of responsibility.
 The controller manufacturer disclaims all liability.
56
The following safety settings are available:
Sub-menu Safety settings
Allow remote access
Show in
Mode menu
Display safety notices Safety notices for a switch output can be deactivated
25.4

Electrical connection

Required user qualification:
ELECTRICAL SPECIALIST
Electrical connection of universal switch outputs may
®
)
only be performed by an ELECTRICAL SPECIALIST as
defined in the chapter User qualification.
IMPORTANT NOTICE!
Do not exceed the maximum currents
®
)
Do not exceed the maximum permissible electrical
currents for each individual relay switch output (max.
4 A) and for the sum of all relay switch outputs being
used in 230 V~ configuration (in sum, also max. 4 A)
Please also refer to the Chapter 230 V~ Power
supply.
The following figure shows the internal wiring for relay switch outputs
OUT1...OUT4, which can be used for universal switch outputs. All
connections shown are run internally as conductor paths.
1
Fuse 4AT
2
230 V~ phase L
(secured with 4 A)
Potential settings:
 Inactive
 Local network
 Local network & Web
Yes / no
here, if the switched function does not yield any
hazards.
for the add-on functions