Part C:
Installation, start-up, maintenance
Required user qualification:
TRAINED SPECIALIST
All activities described in Part C may only be performed
by TRAINED SPECIALISTS as defined in the Chapter
User Qualification.
34
Safety information for performing installation,
start-up, and maintenance work
HAZARD!
Hazard from electrical current
PoolManager
begins to run as soon as there is
®
voltage on the incoming power line. It is possible that
dosing pumps start or that add-on functions are
turned on or switched. Contact with current-carrying
components can lead to an electrical shock.
Potential consequence: Grave health hazard and
death, material damage
Installation and maintenance work on the unit
must always be performed in the volt-free state.
The unit must be secured against turning on
while performing work!
Supplemental component groups have to be
mounted / dismounted in the volt-free state.
Cables also have to be connected in a volt-free
state.
There should always be safety equipment
present that is independent of the controller.
Password protection must be activated as
needed.
The country's local safety requirements must
be met.
Immediately after completing work, all safety
and security equipment must be reinstalled and
rendered functional.
Non-compliance with safety information can
lead to the unit becoming defective, to mortal
danger, and to warranty forfeit.
35

Wall mounting

HAZARD!
The unit is not suitable for installation in areas
exposed to explosion hazards.
35.1

Selecting the installation location

Level, flat surface.
The free space surrounding the unit must be large enough for
trouble-free operation and maintenance. Covers must remain
removable. Be sure that the electrodes are freely accessible in
order to guarantee trouble-free handling.
The control unit's casing opens to the left.
The control unit's display should be approximately at eye level.
At least 20 cm of clearance is needed underneath the unit for
installing hoses.
No parts sensitive to moisture underneath the unit
A damp room DC SCHUKO socket no more than 1.5m away.
All hoses and cables must be installed free from kinks and
abrasion.
No hose line should be longer than 5m.
Hoses must not be run directly over pipes or systems that
transmit heat.
70
Direct sunlight, thermal radiation, frost, and moisture must be
avoided.
Ensure sufficient ventilation.
No current-carrying lines, relays, electric motors, etc. in the near
vicinity.
The installation location should be as close to measuring water
extraction and return as possible.
35.2

Installation

The base plate can be used as a drill template by holding it on the
intended location and marking the drill holes on the wall.
After the base plate is safely anchored to the wall, including
mounted controller and measuring sensory, the covers can be
inserted into the tongue and groove connection supplied.
36

Electrical connection

PoolManager
is designed and built according to the applicable
®
guidelines. Prior to leaving the factory, it was carefully inspected and
departed from the factory in a state free of technical issues.
Hazard-free operation is only possible when all information included in
this manual is observed.
The supply current for the unit must not exceed 240V/50 Hz. The
permissible operating temperature is 0 to 50 °C, permissible air
humidity is 0-90 %.
As is standard with all electrical connections, be sure that all plug
connections are secured against water.
36.1

Measurement grounding

There must be a grounding (protective earth connection) for both
measuring water extraction and return. The ground connections have
to be connected with a safe ground in order to facilitate the conduction
of potential in pool water.
IMPORTANT NOTICE
The ground MUST be installed. Ensure that this
ground functions without issues.
Please always make sure that there is no residual
current to the swimming pool's water. In cases of
doubt, we recommend having measurement taken
professionally.
36.2

Blocking via the circulation pump

PoolManager
is equipped with a double pump lock, which offers the
®
highest level of security. That is why it has 2 separate power
connections, with one power connection directly to the controller and
the other connection supplying the dosing pump.
On the one hand, the flow switch in the measuring cell ensures that
the dosing pump is only turned on when there is sufficient water
flowing through the measuring cell.
On the other hand, the dosing pumps are supplied via a separate
power supply input. That power input absolutely must be connected
such that the dosing pumps are only supplied with power when the
circulation pump is running.
This guarantees that the dosing pump only runs when the pool water
is running through the circulation system.