25.3

Configuration menu

The configuration menus for each individual switch output are set up
identically.
They are called up via the icons
INFO
Designation of universal switch outputs
In all menus in which the universal switch outputs
appear, the switch output designation you entered will
be indicated (e.g. Waterfall)
The following settings are available:
Configuration menu for universal switch outputs
Name
Entry of the freely selectable name (designation) for the switch output.
Operating mode
Selection of operating mode:
 Inactive (Switch output not used)
 Off (Switch output used, but turned off)
 On
 Timer
Timer function
Activate the switch output once for a specified switch-on time.

Programmable timer

Programming timers.

Basic configuration

Basic settings for the switch output.
Safety settings
Safety settings for the switch output.
INFO
Allocation of a relay switch output
A universal switch output can only be activated if you
have allocated a relay switch output to it beforehand
in the Basic Configuration menu.
25.3.1
Programmable timer
This menu provides 6 freely programmable timer intervals for each
switch output.
The timer intervals are displayed in the menu in an easy-to-follow
manner with programmed weekdays and times:
The following settings are possible for each of the 6 time intervals:
Sub-menu Timer interval (1..6)
Weekdays
Selection of one or multiple weekdays on which the
timer interval should be active.
If no weekday is activated, then the entire timer
interval is inactive.
Switch-on time
Time at which switch-on occurs.
Switch-off time
Time at which switch-off occurs
Interval operation
Activation of interval operation
(Periodic switching on and off)
Switch-on interval
Switch-on duration for interval operation.
Switch-off interval
Switch-off duration for interval operation.
25.3.2
Basic configuration
The menu Basic configuration is used to configure the basic settings
for a switch output. This is generally done once upon placing a switch
output into operation.
The following settings are available:
Sub-menu Basic configuration
Relay output
Relay switch output used for the universal switch
output.
Block if missing flow
Yes  Output is turned off if flow signal is missing.
Blocking by filter
Yes  The output is turned off depending on the
pump operation mode
operation mode of the filter pump.
Prerequisite: PoolManager
Blocking by input.
Yes  The output is turned off if the selected input is
in the state indicated.
Blocking by another
Yes  The output is turned off if the other output
output
selected is in the state indicated.
External switch or
See External switch or push-button.
push button
INFO
Terminal block indication
For the relay outputs OUT1 ... OUT4, the terminal block
number is indicated directly in the menu. This is the
number in brackets, e.g. [26] for OUT1.
INFO
Switch OUT4
The relay output OUT4 is designed as a changeover
switch. When active (on), terminal block [31] is turned
on. When inactive (off), terminal block [32] is turned on.
All other switch outputs are designed as simple on / off
switches.
controls the filter pump.
®
55