Safety Settings; Electrical Connection; Universal Switch Inputs In 1 - Bayrol PoolManager Chlorine User Manual

Hide thumbs Also See for PoolManager Chlorine:
Table of Contents

Advertisement

32
31.1.3

Safety settings

HAZARD!
Hazard via remote access
Depending on the form of realisation, hazards may be
created from remote access to the eco mode function.
Potential consequence: Injury,
material damage.
 Release of remote access to the eco mode function
is expressly PROHIBITED for all applications in
which the safety of persons, animals, and property
is not completely guaranteed at all times and under
all circumstances; especially for remote access.
 Safety is exclusively in the system operator's
sphere of responsibility.
 The controller manufacturer disclaims all liability.
The following safety settings are available:
Sub-menu Safety settings
Allow remote access
Potential settings:
 Inactive
 Local network
 Local network & Web
Show in
Yes / no
Mode menu
31.2

Electrical connection

Required user qualification:
ELECTRICAL SPECIALIST
The electrical connection for eco mode may only be
performed by an ELECTRICAL SPECIALIST as
defined in the chapter User qualification.
IMPORTANT NOTICE!
Do not exceed the maximum currents
Do not exceed the maximum permissible electrical
currents for each individual relay switch output (max. 4
A) and for the sum of all relay switch outputs being
used in 230 V~ configuration (in sum, also max. 4 A)
Please also refer to the Chapter 230 V~ Power supply.
Depending on how eco mode is realised, there are various options for
establishing the electrical connection (volt-free, 230 V~,...).
In general, the connection options already described for the universal
switch outputs are available, see Universal switch outputs
connection options.
68
32
Universal switch inputs IN 1 ... IN 4
PoolManager
provides four universal switch inputs that can be
®
connected to external volt-free switches or switch contacts:
Universal switch
input
Description
IN 1 [6]
Switch input IN 1 [terminal block 6]
IN 2 [7]
Switch input IN 2 [terminal block 7]
IN 3 [8]
Switch input IN 3 [terminal block 8]
IN 4 [9]
Switch input IN 4 [terminal block 9]
Several of the potential applications are described in connection with
the various add-on functions, e.g. connection of an external switch or
push-button.
IMPORTANT NOTICE!
Volt-free inputs
The externally connected switch or switch contact
absolutely must be volt-free (free of electrical potential).
Otherwise, residual currents may arise, which can,
among other things, destroy electronic components.
The following figure shows the internal wiring of the input IN 1. The
other inputs IN 2 ... IN 4 are set up identically.
Internal ground connection of terminal b
1
(The b terminals on all four switch inputs are internally linked to
ground)
2
Internal optical coupler for galvanic isolation
3
Signal output for internal processing
4
Externally connected volt-free switch

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poolmanager brominePoolmanager oxygenPoolmanager pro

Table of Contents