38

Winter breaks

NOTE
Do not use buffer solutions that are more than 12
months old.
NOTE
The lifespan on gas electrodes depends on the
operating conditions and the water's properties. It is
normally ca. 12 months; storage time is applied at
50%.
NOTE
Maintenance frequency is only partially dependent
upon utilisation intensity. Chemical strain, for example,
on plastic parts begins immediately upon first contact
with the medium and is not dependent upon the type of
utilisation.
37.4

Cleaning

Clean the unit's surface as needed using a towel that is soft and free
of fuzz. Only use a small amount of water, if necessary.
IMPORTANT NOTICE
Do not use aggressive cleaning products.
37.5

Dosage pump hose replacement

NOTE
Never grease hoses!
NOTE
Only original replacement pump hoses may be used!
HAZARD!
Hazard due to chemicals
Corrosive product residue may come out of the pump
hose when pulled off.
Potential consequence: Grave health hazard
(chemical burns) and material damage
Always be sure to empty pump hoses and feed
lines first.
When necessary, use protective eye wear and
gloves and protect the surrounding area from
escaping product residue using a towel .
HAZARD!
Hazard due to rotating parts
The dosage pump's rotor may start immediately.
Potential consequence: Crushing of fingers!
Ensure that the dosage pump remains separated
from the operating voltage (unplug) when replacing a
hose!
The dosage pump's hose is replaced without removing the rotor.
Remove the empty suction and pressure hoses from the hose
fastener. To do so, loosen the blue clamp screws.
Remove transparent cover 1 from the pump.
Remove transparent cover 2 from the rotor.
Turn rotor 3 such that the flat side faces left and is vertical.
Pull hose fastener 4 from its bracket and lift on the left side.
Turn rotor 3 clockwise and remove the cable while lifting on it
until it is completely free.
To install, perform in the opposite order.
Either the hose can be replaced alone, or the hose and hose fastener
can be replaced jointly.
It is recommended to replace hose and hose fastener jointly.
Art. no.
Designation
127302
Replacement hose set
1.5 l/h (hose with hose
fastener)
127352
Replacement hose set
3.0 l/h (hose with hose
fastener)
127303
Replacement hose set
1.5 l/h (hose with hose
fastener)
127353
Pump hose 3.0 l/h (hose
without hose fastener)
38
Winter breaks
No special measures are necessary for short breaks in usage (e.g.
several days).
For longer operational breaks of multiple weeks, such as the winter
months, the following work must be performed:
Remove suction lances from the canisters and rinse them with
water.
Close packages, store them in a cool and dry location protected
from UV radiation.
Rinse hose pumps with water. To do so, run the pumps in
manual mode.
User Manual PoolManager
®
Application
Chlorine and pH for pool sizes up to ca.
100 m
3
Chlorine and pH for pool sizes of
ca.100 m
3
to ca. 200 m
BayroSoft.
Chlorine and pH for pool sizes up to ca.
100 m
3
Chlorine and pH for pool sizes of
ca.100 m
3
to ca. 200 m
BayroSoft.
NOTE
If only the hose is being replaced, then the following
absolutely must be observed during installation
• The hose sits securely in the grommets.
• Under no circumstances may the hose be twisted
when installed.
• Ensure the hose clip sits securely.
3