7
7.3

Overview of features

7.3.1
Display and operation
Great emphasis was placed on easy-to-follow, simple, and intuitive
operation while developing PoolManager
presented in a modern and attractive manner.
The following is an overview of the significant features and concepts in
the graphic interface.
 Large, high-resolution 7" (18cm) colour TFT
graphics display
 Attractive 16:10 wide format
 Wide VGA resolution (800x400)
 65536 colours
 Energy-saving LED backlight
Simple, intuitive touchscreen operation
 Robust touchscreen with additional full
design foil overlay
 Every touch is confirmed with a signal tone
Icon menu
 Up to 20 high quality icons
 Faster and easier access to all functions
and parameters
 Additional text for each icon in order to
ensure clarity
Standard menu
 Uniform concept for all standard menus
 Uniform operation throughout
Hotkeys
 5 hotkeys for menu navigation and for
important basic functions that are regularly
needed (e.g. help function)
Measurement graph
 Max record length of 1 year
 Max resolution 1 min
 Display of 1 or 2 measured variables
 Display of all important alarm statuses
Mode menu
 Called up using special Mode hotkey
 Various system functions can be turned on
and off quickly and easily
Numerous menu languages available
 Extensive support for special international
characters and complete character sets
(e.g. Cyrillic and Greek)
Individualisation
 Selectable menu style
 Selectable background image
 Selectable icon style
10
. The screen design is also
®
7.3.2
Measuring and control
pH and redox measurement via single-rod measuring cells
(glass electrodes)
free chlorine / bromine measurement via open potentiostatic
measurement (3-electrode system)
Temperature measurement in the measuring chamber (PT1000
sensor)
2 additional temperature inputs for additional functions (PT1000,
KTY83, or KTY16-6 sensors)
Proportional control for all control modules
Minimum dosing rate provides for additional I-(integral)
contribution, i.e. for reliable attainment of the setpoint.
All important control parameters are individually programmable for
each control module (setpoint, alarm thresholds, proportional
range, dead zone (pH), dosing cycle time, minimum dosing rate,
dosing monitoring)
Continuous display of current dosing rate
Conversion of all measured variables via high resolution 10-bit
A/D converter.
1- or 2-point calibration for pH
Simple and precise 1-point calibration for chlorine / bromine
(PoolManager
PRO only)
®
1-point calibration for redox (mV) and temperature
7.3.3
Safety functions
Extensive monitoring and alarm functions
Upper and lower measured value alarms
Flow monitoring
Level warnings and level alarms (canister level)
Dosing monitoring
(monitoring of the attainment towards the setpoint)
Battery alarm (buffer battery for the real-time clock)
Start delay after turning on PoolManager
circulation back on
Automatic blocking of dosing in critical alarm states and during
start delay
Alarm signalisation via
Screen display
Acoustic alarm (can be deactivated)
Alarm relay
Continuous monitoring of correct program operation and
automatic reset in the event of an error.
or after turning
®