6.5 Save Parameter Values

The keypad keys and display work with the memory of the control. When a parameter value is displayed, the displayed value
is the value stored in control memory. The changes are written to non-volatile memory and are stored even when power is
removed. Normal control operation can resume when power is restored.
Keypad memory is only used to backup the four parameter tables stored in control memory. This means that after the
parameters are configured for the application and the control operation is as desired, a copy of the parameters can be
saved to keypad memory as a backup copy. This backup copy can be restored at any time. This is useful to restore program
operation after a firmware update or to make several controls operate the same. It prevents having to make the changes to
each control individually.
Action
Press Menu
Press Enter to edit
Keypad Setup
parameters.
Press Enter to edit
parameter.
Press Enter to load the
parameter table values
from control memory to
keypad memory.
A copy of all four parameter tables have now been saved to non-volatile keypad memory.
MN765
Description
Go to the Advanced Prog
Level 1 Keypad Setup block.
PARAMS TO KEYPAD
Scroll to
Display
PRESET SPEEDS
RAMP RATES
JOG SETTINGS
KEYPAD SETUP
INPUT SETUP
STATUS
BACK
PROG
KEYPAD SETUP
PARAMS TO KEYPAD
No
STATUS
F1310
BACK
EDIT
KEYPAD SETUP
PARAMS TO KEYPAD
Yes
F1310
STATUS
BACK
PROG
KEYPAD SETUP
PARAMS TO KEYPAD
No
F1310
STATUS
BACK
Comments
Press "Enter" to select.
Press "Enter" to change
parameter value.
Note that T1 is missing from the
parameter number. It is not part
of the stored parameter table
values T1, T2, T3 and T4.
Press
to change value to YES.
Press "F2" to return to Keypad
Setup menu.
Using the Keypad 6-7