Parameter (Number)
Block Title
DOWNLOAD SELECT (1311)
KEYPAD
SETUP
(Continued)
KEYPAD TO PARAMS (1312)
KEYPAD CONTRAST (1313)
BACKLIGHT (1314)
LOC TORQUE MODE (1315)
Closed/Open Vector Only
LOC TORQUE REF (1316)
Closed/Open Vector Only
OPERATING MODE (1401)
INPUT
SETUP
Standard Run 2Wire (1)
Standard Run 3Wire (2)
15 Preset Speeds (3)
Fan & Pump 2Wire (4) Operation in Fan & Pump 2 Wire controlled by digital inputs at J2.
Fan & Pump 3Wire (5) Operation in Fan & Pump 3 Wire controlled by digital inputs at J2.
3Spd Ana 2Wire (7) Provides 2 Wire control and allows selection of 3 Preset Speeds.
3Spd Ana 3Wire (8) Provides 3 Wire control and allows selection of 3 Preset Speeds.
7-4 Parameter Descriptions
Table 7-1 Level 1 Parameter Block Definitions Continued
Selection (Value)
Preset Value: 0
Range: 0 - 2
All (0) All parameters.
Motor (1) Motor parameters only.
Other (2) All parameters except Motor parameters.
Selects parameters to download (All, Motor or Other) with "Keypad to Params"
(P1312). See Appendix B for notation of which parameters are motor related.
Preset Value: 0
Range: 0 - 1
No (0) No action.
Transfers the parameter settings stored in keypad memory to the control memory
Yes (1)
(flash).
Preset Value: 50
Range: 0 - 100%
Sets LCD contrast: 0=dimmest, 100=brightest.
Preset Value: 1
Range: 0 - 1
Off (0) Sets the Keypad Display backlight OFF.
On (1) Sets the Keypad Display backlight ON.
Preset Value: 0
Range: 0 - 1
Off (0) Disables local torque mode.
On (1) Enables local torque mode operation.
Preset Value: 0.00
Range: -100.00 to 100.00%
Local torque mode reference value.
Preset Value: 0
Range: 0 - 16
Keypad (0) Drive operates from keypad only.
Drive operates from digital inputs and command source. Preset Speed 1 may also
be selected.
Drive operates from digital inputs and command source. Preset Speed 1 may also
be selected.
Operation in 15 Preset Speeds 2 Wire Mode is controlled by digital inputs at J2.
Speeds set in parameters P1001 to P1015.
The Process Control provides an auxiliary closed loop general purpose PID set
Process Control (6)
point control.
Electronic Potentiometer provides digital inputs for Speed Increase and Speed
E-Pot 2Wire (9)
Decrease. Also provides 2 digital inputs for selection of E-Pot or "Command
Source" (1402), Preset Speed 1, and Preset Speed 2.
Electronic Potentiometer provides digital inputs for Speed Increase and Speed
E-Pot 3Wire (10)
Decrease. Also provides a digital input for selection of E-Pot or "Command Source"
(1402).
Network (11) Provides Bipolar speed or torque control.
Provides a seven segment speed profile for cyclic operation or test cycle. See
Profile Run (12)
Level 3, Profile Run Block.