Baldor VS1GV21-1B Installation & Operating Manual page 153

Vs1gv series ac closed vector control
Table of Contents

Advertisement

ID
0
1
Digital Output 1 On
2
Digital Output 1 Off
3
Digital Output 2 On
4
Digital Output 2 Off
5
Relay Output 1 On
6
Relay Output 1 Off
7
Relay Output 2 On
8
Relay Output 2 Off
9
Increment P107
10
Decrement P107
11
Reset P107
12
Digital Output 1 On with Inc
13
Digital Output 1 Off with Inc
14
Digital Output 1 On with Dec
15
Digital Output 1 Off with Dec
16
Digital Output 1 On with Reset
17
Digital Output 1 Off with Reset
18
Relay Output 1 On with Inc
19
Relay Output 1 Off with Inc
20
Relay Output 1 On with Dec
21
Relay Output 1 Off with Dec
22
Relay Output 1 On with Reset
23
Relay Output 1 Off with Reset
Level 1, Output Setup Block parameters P1501-P1504 select the digital/relay output functions. P107 is the RTC counter
parameter.
Message Module (P3603 - 3604)
Message Module parameters P3603 - 3604 set the messages to be scheduled. Message selections are shown in Table 12-3.
ID
0
None (default)
1
Clean Filter(s)
2
Change Filter(s)
3
Apply Oil/Lubricate
4
Service Motor
5
Service Drive
6
Service Coolant System
7
Service Heating System
8
MN765
Table 12-2 Actions (P3601 & 3602)
ACTION
None
No action assigned. Default setting.
Digital output 1 is turned on. P1501 set to RTC.
Digital output 1 is turned off. P1501set to RTC
Digital output 2 is turned on. P1502 set to RTC
Digital output 2 is turned off. P1502 set to RTC
Relay output 1 is turned on. P1503 set to RTC
Relay output 1 is turned off. P1503 set to RTC
Relay output 2 is turned on. P1504 set to RTC
Relay output 2 is turned off. P1504 set to RTC
Increments the RTC counter parameter
Decrements the RTC counter parameter
Resets the RTC counter parameter
Performs digital I/O with P107 increment
Performs digital I/O with P107 increment
Performs digital I/O with P107 decrement
Performs digital I/O with P107 decrement
Performs digital I/O with P107 reset
Performs digital I/O with P107 reset
Performs digital I/O with P107 increment
Performs digital IO with P107 increment
Performs digital IO with P107 decrement
Performs digital IO with P107 decrement
Performs digital IO with P107 reset
Performs digital IO with P107 reset
Table 12-3 RTC Message 1&2 Parameters (P3603 & P3604)
ACTION
No message active
Time to do periodic cleaning of filter(s)
Time to change out the filter(s)
Apply oil and/or lubricant necessary areas of the system
Check motor cables, encoder, clean motor etc.
Check drive cables, clean panels and keypad display etc.
Check coolant pressures/levels, check for leaks, top off as needed
Check for gas leaks, clean filters, blowers and connections
RTC Alarm
Generic real-time clock alarm
DESCRIPTION
DESCRIPTION
Monitor and RTC Description 12-7