Setting the Detection Surface Selection

Detection surface selection:
The default value is FIRST. Setting the value to MAX can decrease incorrect
CONTENTS
measurements caused by diffused reflection or multireflection due to the shape of the
workpiece.
INTRODUCTION
Sensor Head
PREPARATION
FOR
MEASUREMENT
FLOW OF
OPERATION
BASIC
SETUP
MAIN

APPLICATIONS

& SETTING
METHODS
Procedure for setting up detection surface selection
Height
Set to the MENU mode
Steps
and
Warpage
Double
Sheet
Return to RUN mode
Detection
Thickness
1
Set to the MENU mode
Positioning
Button
Eccentricity
Operation
and Surface
Deflection
DETAILED
Hold down for
3 seconds
SETTINGS
TROUBLE-
SHOOTING
SPECIFI-
CATIONS
INDEX
Press to display.
SETTING
TRANSITION
CHARTS
120

Setting the Detection Surface Selection

Setting channels used when connecting multiple units: Each CH
Multireflection
Measurement
while moving
NEAR
Measurement performed on
the NEAR side
(with the FIRST setting)
Correct reflection
Multireflection
Detection surface
selection setting
Setting completed
Display
Hold down the
Lit
three seconds to switch to the
MENU mode.
Press the
Press the
display to
the detail menu.
Press the
the setting.
Correct
reflection
FAR
Description of Operation
button for
button to display
.
button to set the
to set display of
button to apply
Measurement performed with
correct reflection components
(with the MAX setting)
Explanation of
Selection Menu
* This step is not required if
detail menu display is
already set to ON in the
MENU mode.
ZX2 User's Manual