Setting The Step Input Detection Pulse Width [Step Setting] - Omron FZ3 User Manual

Vision sensor xpectia fz3 series
Hide thumbs Also See for FZ3:
Table of Contents

Advertisement

3.
Set the trigger detailed settings as required.
6
Trigger signal
When phase A
When phase Z

Setting the STEP Input Detection Pulse Width [STEP Setting]

This setting is performed as a countermeasure against STEP input chattering and to prevent operation
malfunctions due to entrance of noise.
When Filter Setting Value Is 100 μs (Initial Value)
The STEP signal is detected as being on at the point it is on continuously for at least 100 μs, and
measurement begins at this point.Accordingly, STEP signal detection is delayed by an amount of time
equivalent to the set filter value. Also, when turning from ON to OFF, the OFF filter fixed at 500 μs is
activated and the STEP signal is detected as OFF when it is off for at least 500 μs.
142
Setting the System Operation Environment
Setting item
[Factory default]
[Phase A]
Phase Z
[Every trigger pulse]
Pulse reset
Every rotation (Pulse Z)
timing
STEP
Phase A
[0] to 65536
Support
[Checked]
backlashing
Unchecked
Trigger in
Checked
backlashing
[Unchecked]
Pulse reset
[Every trigger pulse]
timing
STEP
Phase Z
[0] to 1023
Set value
Sets the trigger signal.
Sets the timing for resetting.
Sets the pulse width.
Sets whether the rotation direction is
detected.
Sets whether a trigger is produced
during reverse rotation.
Sets the timing for resetting.
Sets the pulse width.
Description
FZ3 User's Manual