Button
Display
Operation
Select the
Press to select
desired value.
3
Smart tuning
Select from one of the following three methods to execute smart tuning:
(1) Tuning of a single stationary workpiece: Single smart tuning
(2) Tuning of multiple stationary workpieces: Multi-smart tuning
(a mix of workpieces having different color and state)
(3) Tuning of workpieces having different surface states: Active smart tuning
(execution of tuning while workpieces are moving)
(1) Tuning of a single stationary workpiece: Single smart tuning
Button
Display
Operation
Pressing down
Hold down for
1 second
Pressed down
Flashing
ZX2 User's Manual
Description of Operation
Press the
button to select the
response time.
Press the
button to apply
the setting.
Required
Description of Operation
Set the reference workpiece in
place.
Press the
button for one
second. When
is displayed, release
your finger from the button to
start execution of smart tuning.
Explanation of
Selection Menu
Select the response time to
match the size and moving
speed of the sensing object.
to
60 µs, 120 µs, 240 µs, 500 µs,
1 ms, 2 ms, 4 ms, 8 ms, 12 ms,
20 ms, 36 ms, 66 ms, 128 ms,
250 ms, 500 ms
* After the response time is
changed, the smart tuning
results are cleared, so be
sure to re-execute tuning.
Explanation of
Selection Menu
If "
sub-display for three
/
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
CONTENTS
INTRODUCTION
PREPARATION
FOR
MEASUREMENT
FLOW OF
OPERATION
BASIC
SETUP
MAIN
APPLICATIONS
& SETTING
METHODS
Height
Steps
and
Warpage
Double
Sheet
Detection
Thickness
Positioning
Eccentricity
" flashes on the
and Surface
Deflection
DETAILED
SETTINGS
TROUBLE-
SHOOTING
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
81
Smart Tuning

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents