Omron ZX2-LDA41 User Manual page 139

Zx2 series smart sensors / laser displacement sensors cmos type
Table of Contents

Advertisement

Model
ZX2-LD50L
Item
Optical system Diffuse-reflective
Light source
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1 mW max.
(wave length)
EN class 2, FDA class 2 (*5)
Measurement
50 mm
center distance
Measurement
±10 mm
range
Beam shape
Line
Beam size (*1) Approx. 60 µm x 2.6 mm Approx. 60 µm dia.
Resolution (*2) 1.5 µm
Linearity (*3)
±0.05% F.S.
(40 to 50 mm)
±0.1% F.S.
(entire range)
Temperature
0.02% F.S./°C
characteristic (*4)
Ambient
Incandescent lamp: 10,000 lx max. (on light receiving side)
illumination
Ambient
Operating: 0 to +50°C, Storage: –15 to +70°C (with no icing or condensation)
temperature
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute
Vibration resistance
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes each in X, Y, and Z directions
(destruction)
Shock resistance
300 m/s
2
(destruction)
Degree of
IEC60529, IP67
protection
Connection
Connector connection (standard cable length: 500 mm)
method
Weight
Approx. 160 g (main unit only: approx. 75 g)
(packed state)
Materials
Case and cover: Polybutylene terephthalate, Optical window: Glass, Screw sections:
Brass, Cable: PVC
Accessories
Instruction sheet, ferrite core x 1 (made by TDK Corp. ZCAT1730-0730A), laser warning
label (English), FDA certification label
(Note) Highly reflective objects can result in incorrect detection by causing out-of-range measurements.
(*1) Beam size: The beam size is defined by 1/e
(measured value).
Incorrect detection may occur if there is light leakage outside the defined spot and the material around
the sensing object is more reflective than the sensing object.
(*2) Resolution: The resolution is the deviation (±3σ) in the analog output when connected to the ZX2-LDA
Amplifier Unit. (The resolution is measured with the standard reference object (white ceramic), at the
measurement point when the response time of the ZX2-LDA is set to 128 ms.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the
distance accuracy.
The resolution may be adversely affected under strong electromagnetic fields.
(*3) Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring
the standard reference object.
The linearity and measurement values vary with the object being measured. F.S. is the entire
measurement range. (ZX2-LD50 :20mm)
(*4) Temperature characteristic: The temperature characteristic is measured at the measurement center distance
with the Sensor and reference object (OMRON's standard reference object) secured with an aluminum jig.
(*5) Categorized as Class 2 by IEC60825-1 criteria in accordance with the stipulations of the FDA standard
Laser Notice No. 50, and registered with CDRH (Center for Devices and Radiological Health) (accession
number: 1020665)
ZX2 User's Manual
ZX2-LD50
Spot
±0.1% F.S.
(40 to 50 mm)
±0.15% F.S.
(entire range)
3 times each in six directions (up/down, left/right, forward/backward)
(13.5%) of the strength of the beam at the beam center
2
ZX2-LD100L
100 mm
±35 mm
Line
Spot
Approx. 110 µm x 2.7 mm Approx. 110 µm dia.
5 µm
±0.05% F.S.
±0.1% F.S.
(65 to 100 mm)
(65 to 100 mm)
±0.1% F.S.
±0.15% F.S.
(entire range)
(entire range)
Specifications and Dimensions
ZX2-LD100
CONTENTS
INTRODUCTION
PREPARATION
FOR
MEASUREMENT
FLOW OF
OPERATION
BASIC
SETUP
MAIN
APPLICATIONS
& SETTING
METHODS
Height
Steps
and
Warpage
Double
Sheet
Detection
Thickness
Positioning
Eccentricity
and Surface
Deflection
DETAILED
SETTINGS
TROUBLE-
SHOOTING
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
139