Connected IP addresses
Special Data Register
D8350-D8353
D8354-D8357
D8358-D8361
D8362-D8365
D8366-D8369
D8370-D8373
D8374-D8377
D8378-D8381
HMI module connection status information and connected IP address
The connection status for the HMI module connection number specified by D8429 is stored in special internal relays and special
data registers.
The status of the connection to an HMI module external device can be checked with special internal relay M8232.
The relay is on when connected to the external device and off when not connected.
The connected IP address can be checked with special data registers D8430 to D8433.
Read specified target connection number
Special Internal Relays
D8429
Status information
Special Internal Relays
M8232
Connected IP Address
Special Internal Relays
D8430-D8433
3-12
ETTINGS
Connection 1 Connected IP Address
Connection 2 Connected IP Address
Connection 3 Connected IP Address
Connection 4 Connected IP Address
Connection 5 Connected IP Address
Connection 6 Connected IP Address
Connection 7 Connected IP Address
Connection 8 Connected IP Address
HMI module
read target connection
number
HMI module
connection status
HMI connection
Connected IP Address
FC6A S
M
S
A
ERIES
ICRO
MART
Description
When communication has been established between an
external device and a connection, the IP address of the
connected external device is stored in special data
registers as shown below.
Example: IP Address: aaa.bbb.ccc.ddd,
D8350=aaa, D8351=bbb, D8352=ccc, D8353=ddd
Description
Reflects the connection information for the specified number
to D8430 through D8434 and M8232.
When 0 is specified, the target devices are all set to 0.
If a connection not that does not exist is specified, the
operation is the same as when 0 is specified.
Description
On when the connection specified with D8429 is connected to
an external device and off when there is no connection.
Description
When communication has been established between an
external device and the connection specified by D8429, the IP
address of the connected external device is stored in special
data registers as shown below.
Example: IP Address: aaa.bbb.ccc.ddd,
D8350=aaa, D8351=bbb, D8352=ccc, D8353=ddd
-
-O
T
C
LL
IN
NE
YPE
OMMUNICATION
M
FC9Y-B1730
ANUAL
Read/Write
R
Read/Write
R/W
Read/Write
R
Read/Write
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents