IDEC FC6A-C16K1CE Communications Manual page 103

Fc6a series microsmart all-in-one type
Hide thumbs Also See for FC6A-C16K1CE:
Table of Contents

Advertisement

Check that TXD is selected in the Type box and select Port 1 in the Port No. box. Then, click Insert.
2.
The Data Type Selection dialog box appears. You will program source device S1 using this dialog box.
3.
Click Constant (Hexadecimal) in the Type box and click OK. Next, in the Constant (Hexadecimal) dialog box, type 02 to
program the start delimiter STX (02h). When finished, click OK.
Since the TXD (Transmit) dialog box reappears, repeat the above procedure. In the Data Type Selection dialog box, click
4.
Variable (DR) and click OK. Next, in the Variable (Data Register) dialog box, type D0010 in the DR No. box and click
BCD to ASCII to select the BCD to ASCII conversion. Enter 4 in the Digits box (4 digits) and 2 in the REP box (2 repeat
cycles). When finished, click OK.
Again in the Data Type Selection dialog box, click BCC and click OK. Next, in the BCC dialog box, enter 1 in the
5.
Calculation Start Position box, select ADD for the Calculate Type, click Binary to ASCII for the Conversion Type, and
click 2 for the Digits. When finished, click OK.
FC6A S
M
S
A
-
-O
ERIES
ICRO
MART
LL
IN
5: U
SER
T
C
M
NE
YPE
OMMUNICATION
ANUAL
C
I
OMMUNICATION
NSTRUCTIONS
FC9Y-B1730
5-27