8: J1939 C
OMMUNICATION
Designated CA
For each added CA, these settings configure the address and NAME of the CA to exchange messages with and the transmitted and
received messages.
■ Address Settings tab
This tab configures the address and NAME of the CA selected on the CA list.
(1)
(2)
(3)
(4)
(1) Address
Sets the address of the CA to exchange messages with from between 0 and 254.
When Input NAME and PGN by hexadecimal value check box is selected, enter them as hexadecimal values.
Example: When hexadecimal: 01, F0, etc.
(2) NAME
Sets the CA NAME in 64 bits. If CA NAME is not defined, set it to 0.
When Input NAME and PGN by hexadecimal value check box is selected, enter them as hexadecimal values.
Example: When hexadecimal: 123456789ABCDEF1, 0000FFFFFFFFFF0A, etc.
The device name (NAME) is composed of the set values in the device name field list (3). When the device name (NAME) is
changed, those changes are reflected under Preset Value in the device name field list.
(3) Device name field list
Displays each field of the device name (NAME) (2). When a Preset Value is changed, the result is reflected in the device
name (NAME).
(4) Comment
Sets a comment for the CA as a maximum of 127 characters. This is reflected in the CA list under Designated CA.