11.1.5 Remote I/O Function (F Mode)

Item
I/O allocation method
Slave unit I/O number
allocation method
Slave unit registration
method
Connectable slave unit
Transmission information
monitoring method
I/O map mount allocation
(Note 1): For FP7, the base word number of FP7 WM Unit is a reference.
(Note 2): For FP2SH, the base word number set by the system register (remote I/O allocation) is a reference.

11.1.6 Serial Communication Unit

Item
Remote programming
MEWTOCOL-DAT ASCII
transmission by SEND
instruction
11.1.7 No. of Occupied I/O Points
Item
W mode
W2 mode
F mode
(Note 1): For FP7 (W mode/W2 mode), they are occupied as flags for controlling SEND/RECV instruction.
(Note 2): For FP7 (F mode), the number of occupied points varies according to the number of I/O points allocated to
the remote I/O part.
(Note 3): In the system of FP2SH, they are occupied for one words (16 points). (It can be set to 0 point by the system
register.
11.1 Compatibility with Conventional Model FP2SH
FP7
Master unit base number + No. of I/O
points (Note 1)
The starting numbers for the Input X
and output Y of the same unit number
are the same. (FP7 I/O allocation
method)
Unit configuration
FP I/O terminal unit
FP I/O terminal board
Read by PMGET instruction
System relays, system data registers
For executing the mount registration, it
is necessary to register "F link unit" in
the I/O map in advance.
FP7
Remote programming is not available
from Serial Communication Unit
(product no. AFP7NSC).
Not available
Sending MEWTCOL-COM commands
by SEND/RECV instruction is available.
FP7
Input: 1 word / Output: 1 word (Fixed)
Input: 1 word / Output: 1 word (Fixed)
Input: 256 word / Output: 256 word
(Max.)
FP2SH
Master unit base number (Note 2)
Allocate in the order of the input X and
output Y.
(FP2 I/O allocation method)
System register I/O map registration
FP I/O terminal unit
FP I/O terminal board
FP2 Slave Unit
Special internal relays, special data
registers
-
FP2SH
Remote programming is available (via
MEWNET-W/MEWNET-W2) from CCU
(Computer Communication Unit
(product no. AFP2462)).
Remote programming is not available
from MCU (Multi Communication Unit
(product no. AFP2465)).
MEWTOCOL-DAT ASCII transmission
by SEND instruction is available from
CCU (Computer Communication Unit).
FP2SH
16SE(0SE)
11-5