7.3.2 Specifications and Restrictions

 Specifications
Item
Supported function
Hierarchy
Corresponding port of CPU unit
Transmission path setting function
W
mode
Protocol and
size capable
of relaying
W2
mode
MEWTOCOL7 (Note 4)
Available
transmission
MEWTOCOL-COM
path
MEWTOCOL-DAT
(Note 1) (Note 5)
(Note 1): The remote programming function and data transfer function (transfer by SEND/RECV instructions) are
available for PLCs in the same hierarchy (depth 0). They cannot be executed for PLCs in the different hierarchy
(depth 1).
(Note 2): Slot numbers are set in the range of 01h to 10h (1 to 16).
(Note 3): The relay position for the FP7 CPU is specified with a slot number. The depth is selected from 0 or 1.
(Note 4): For communicating with MEWTOCOL7, the system must consist of MEWNET-W2 and FP7 only.
(Note 5): Data must be sent by the minimum size limited in the transmission path.
 Other restrictions
Item
Relay from W mode to W mode
Relay from W mode to W2 mode
Unit
Relay from W2 mode to W mode
configuration
Relay from W2 mode to W2 mode
Relay to the built-in ET-LAN in the
CPU
Simultaneous transmission of commands
Specifications
Computer link
Max. 2 hierarchies (Depth 0, depth 1)
USB port / COM0 port
Set it to the PLC communication port by MEWTCOL-COM
command (0C, LC). The transmission path information is held
in case of power outage. (Note 2) (Note 3)
MEWTOCOL7
Not available
MEWTOCOL-COM
118 bytes per frame
MEWTOCOL-DAT
118 bytes per frame
MEWTOCOL7
4 k bytes per frame
MEWTOCOL-COM
2 k bytes per frame
MEWTOCOL-DAT
2 k bytes per frame
Source -> (Relay station) -> Destination
FP7→(FP7)→FP7
FP7→(FP7)→FP7
FP7→(FP2)→FP7
FP7→(FP2)→FP2
FP2→(FP2)→FP7
FP2→(FP7)→FP7
Specifications
Available only when the units in W mode are two. When
there are more than three units, it cannot be used as the
relay station.
Not available
Not available
There is no restrictions when the installed units are up to
4 units (i.e. max. connectable number of units).
Not available
Communication cannot be performed when another
command for the same function (computer link, data
transfer, remote programming) is sent to the same relay
station
7.3 Hierarchy Link