Elements which compose command responses
Number
Name
①
Header
②
Destination
③
Identification code
④
Command code
⑤
Slot no.
⑥
Response code
⑦
Error code
⑧
Check code
⑨
Terminator
Description
% or <
"EE" (Fixed): Specify the own unit.
"#": Indicates a command.
"$": Indicates a normal response.
"!": Indicates an error response.
"0C": Indicates the access link unit command.
"0x01" to "0x10": For the FP7 MW Unit, specify slot numbers.
Specify slot numbers (01 to 16) converted to hexadecimal.
"0C": It is returned for a normal response.
An error code is returned when an error occurs.
BCC code is stored.
"CR" (0D:Hex)
7.4 Relevant Information
7-11