Emergency Stop Sense Input (Tb102); Figure 2-10: Estop Sense Input (Tb102); Table 2-13: Tb102B Estop Pin Assignment; Table 2-14: Electrical Noise Suppression Devices - Aerotech A3200 Hardware Manual

Nmark cls
Hide thumbs Also See for A3200:
Table of Contents

Advertisement

Nmark CLS Hardware Manual

2.4.1. Emergency Stop Sense Input (TB102)

The ESTOP sense input is used to monitor the state of an external safety circuit only. This state is indicated
by the software and may be used to facilitate system restart. This ESTOP sense input is not intended to be a
complete safety system.
W A R N I N G :  The user is responsible for assessing operator risk levels and designing the
external safety circuits appropriately.
The ESTOP input is scaled for an input voltage of 5-24 volts.
If the ESTOP bit is enabled in the FaultMask axis parameter, the ESTOP input must be driven to prevent the
ESTOP fault condition.
ESTOP SWITCH
+
24VDC
-
Table 2-13:
TB102B ESTOP Pin Assignment
Pin #
Label
Description
7
ES+
Emergency Stop Opto-Isolated Input +
8
ES-
Emergency Stop Opto-Isolated Input -
N O T E :  Connecting the ESTOP input to a relay or other noise producing device requires the use of noise
suppression devices such as those in
suppress transient voltages.
Table 2-14:
Electrical Noise Suppression Devices
Device
RC (.1uf / 200 ohm) Network
Varistor
www.aerotech.com
ESTOP+
TB102-B7
221
ESTOP-
TB102-B8
221
Figure 2-10:
ESTOP Sense Input (TB102)
Table
2-14. These devices are applied across the switched coil to
Aerotech P/N
EIC240
EID160
Chapter 2
Installation and Configuration
1K 1/2W
.47
PS2806-1
1K 1/2W
Electrocube RG1782-8
Littelfuse V250LA40A
+3.3V
10K
In/Out/Bi
Input
Input
Third Party P/N
31