Installation and Configuration
TB101-A
OUTPUT COMMON +
OUTPUT
SWITCHES
OUTPUT COMMOM -
EACH OUTPUT 60 mA MAXIMUM
1
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
3
Figure 2-16:
TB101A
OUTPUT COMMON +
OUTPUT
SWITCHES
OUTPUT COMMON -
CONNECTION REQUIRED
1
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
3
Figure 2-17:
42
TB101-A1
OPTOOUT 7
1
TB101-A9
OPTOOUT 6
TB101-A8
OPTOOUT 5
TB101-A7
OPTOOUT 4
TB101-A6
OPTOOUT 3
TB101-A5
OPTOOUT 2
TB101-A4
OPTOOUT 1
LOAD
TB101-A3
+
OPTOOUT 0
LOAD
TB101-A2
-
+
LOAD
-
2
TB101-A10
CONNECTION REQUIRED
2
Outputs Connected in Current Sourcing Mode
1
TB101-A1
+
LOAD
-
OUTPUT 7
2
+
TB101-A9
LOAD
-
OUTPUT 6
TB101-A8
OUTPUT 5
TB101-A7
OUTPUT 4
TB101-A6
OUTPUT 3
TB101-A5
OUTPUT 2
TB101-A4
OUTPUT 1
TB101-A3
OUTPUT 0
TB101-A2
TB101-A10
EACH OUTPUT 60 mA MAXIMUM
2
Outputs Connected in Current Sinking Mode
Chapter 2
Nmark CLS Hardware Manual
LOAD
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
3
+
LOAD
-
+
-
5-24 VDC
+
-
5-24 VDC
+
-
+
LOAD
-
+
LOAD
-
3
www.aerotech.com