Refer to "3 (II). Tool Offset (M system)" for M system.

3.1.3 Tool Wear and Tool Length Data Setting Mode (incremental/absolute)

There are two types of selection method in the absolute value setting or incremental value setting for
the tool offset data: the mode selection method and the menu selection method.
The required method is selected with the parameter #1136 optype.
(Old)
(Example) Incremental/absolute value setting
Display
#2 X
-100.000
(1) Mode selection method (#1136=0)
(a) Change over to the incremental value setting mode
Set I in # ( ), then press the
# ( I) X (
(b) Change over to the absolute value setting mode
Set A in # ( ), then press the
# ( A) X (
(Note) The mode is held even if the screen is changed or the power is turned OFF.
(New)
Setting
• Incremental value setting
# (2) ( -
• Absolute value setting
# (2) ( - 100.1)
key.
INPUT
) Z (
)
"#1: INC." is highlighted, and the mode becomes the
incremental value setting mode.
key.
INPUT
) Z (
)
"#A: ABS." is highlighted, and the mode becomes the
absolute value setting mode.
I-78
3. Tool Offset (L system)
3.1 Wear Data
Absolute
setting
Incremental setting
Display
0.1)
#2 X-100.100
#2 X-100.100
[TOOL DATA]
#I:INC.
#A:ABS.
[TOOL DATA]
#I:INC.
#A:ABS.