(c) Buffer correction will be canceled if another screen is opened or reset is executed during the
correction. The corrected details will not be reflected.
(d) Operation cannot be started during buffer correction. The "M01 Operation alarm 0013" will
occur.
(e) If there is no ; (EOB) in the last block edited when
Press the
key.
INPUT
1) ";" is added to the end of the N130 block.
is pressed, it will be added automatically.
INPUT
N125 G01 X80. Y195.F50.;
N126 Y150.;
N127 G02 X100. Y185. R20.;
N128 G01 X110.;
N129 G01 X120.;
N130 G01 X130.
N124 G00 X68. Y201.;
N125 G01 X80. Y195. F50.;
N126 Y150.;
N127 G02 X100. Y185. R20.;
N128 G01 X110.;
N129 G01 X120.;
N130 G01 X130.;