2.3 Turning Power ON, Memory Initialization and Parameter Settings
1) Turning power ON
Confirm the cable connections, etc., before turning the power ON. Especially take care to the
power system connections.
Confirm that the communication terminal screen can be changed over after turning the power ON.
2) Setting of basic specification parameters and initialization of memory
(1) Press the [TOOL/PARAM] function selector key on the communication terminal.
(2) Press the "Menu" key corresponding to the "Menu" displayed on the bottom of the screen.
Change the menu display, find the menu display "SETUP", and press that "Menu" key.
(3) The message "Open the setup parameter?" will display on the screen. Press
then
INPUT
(4) The first page of the basic parameters for setup will display, so refer to the section on the
parameters and set as required. (Parameters #1001 to 1019)
(5) Press the "NEXT PAGE" key on the right of the "Menu" keys, and display the second page of
the basic parameters.
(6) Refer to the section on the parameters and set the items as with the first page. (Parameters
#1025 to 1043)
(7) Set parameter #1060
one-touch setup.
[Procedures for one-touch setup]
(a) Set "#1060 SETUP" to "1".
(b) Set "Y".
(c) Set "Y".
The basic parameters and memory will be initialized.
(8) Turn the control unit's input power OFF and ON once.
(9) This completes the initialization of the memory.
3) Setting of axis specification parameters
(1) Press the [TOOL/PARAM] function selector key on the communication terminal.
(2) Press the "Menu" key corresponding to the "Menu" displayed on the bottom of the screen.
Change the menu display, find the menu display "SETUP", and press that menu key.
(3) The message "Display setup parameters?" will display on the screen. Press
key.
INPUT
(4) Press the "Axis Parameter" menu key. (Five pages in all.)
(5) Refer to "Setup parameters" section and set each item.
CAUTION
Do not change setup parameters without prior approval from the machine maker.
2.3 Turning Power ON, Memory Initialization and Parameter Settings
key.
SETUP
on the second page to "1" (normally it is set to "0"), and perform
2. Start up and Adjustment Procedure
The operation message "BASE PARA.
SET? (Y/N)" will appear.
The standard parameter will be set.
The operation message "FORMAT?
(Y/N)" will appear.
Formatting will start.
III-6
key, and
Y
key, and then
Y