Plc Interface Signal Forcible Definition (Single-Shot Type) - Mitsubishi Electric EZMotion-NC E68 Series Operation Manual

Table of Contents

Advertisement

7.4.3 PLC Interface Signal Forcible Definition (Single-shot Type)

This function is used to forcibly define signals to check the PLC functions.
This function is available for the following device numbers: X, Y, U, W, S, M, G, F, L, E, T, Q, C, B, D,
and R.
(1) Mode setting
Set the device number to be forcibly set in DEVICE ( ), definition data in DATA ( ), and 1 in
MODE ( ), then press the
of one cycle of user PLC.
(Example 2)
Set M23 in DEVICE (
1 in DATA (
), and
1 in MODE (
).
Press the
key.
INPUT
Data is not displayed in the SET DATA field at the screen top.
CAUTION
When forcibly setting (forcibly outputting) data on the I/F diagnosis screen during machine
operation, pay careful attention to the sequence operation.
(Note) An input signal (X or U) to the PLC is updated at the beginning of each cycle of the PLC.
Therefore, the signal, once forcibly defined in single-shot type mode, is restored after one
cycle.
key. The setup data is processed and forcibly defined at the top
INPUT
),
M0016 is displayed at the beginning and bit 7 changes
to 1. (If device M23 OUT instruction comes within one
cycle of user PLC, the sequence processing results
will follow.)
I-271
7. Diagnosis
7.4 PLC Interface Diagnosis
[PLC-I/F]
<SET DATA>
76543210
HEX
M0000 oooooooo
00
M0008 ooooo1o1
05
M0016 oooooooo
00
M0024 o1o1oooo
50
DEVICE
DATA
MODE
( M23 ) (
1 )
( 1)
ALARM
SERVO
SPINDLE
[PLC-I/F]
<SET DATA>
76543210
HEX
M0016 oooooooo
80
M0024 ooooo1o1
50
M0032 oooooooo
A3
M0040 o1o1oooo
82
ALARM/DIAGN 4
76543210
HEX
D0005
oooooooo
00
o11oo1oo
64
D0006
1oooooo1
81
ooooo1oo
04
DEVICE
DATA
MODE
(
) (
)
( )
PLC-I/F
MENU
ALARM/DIAGN 4
76543210
HEX
D0005
oooooooo
00
o11oo1oo
64
D0006
1oooooo1
81
ooooo1oo
04