7.4.4 PLC Interface Signal Forcible Definition (Modal Type)

This is PLC interface signal forcible definition of modal type. Once it is set, it is held until canceled.
The device signals that can be set by using this function are X, Y, U, W, S, M, G, F, L, E, T, Q, C, B, D
and R.
(1) Mode setting
Set the device number to be forcibly defined in DEVICE ( ), definition data in DATA ( ), and 2 in
MODE ( ), then press the
(Example 3)
Set X8 in DEVICE (
1 in DATA (
), and
1 in MODE (
).
Press the
key.
INPUT
A maximum of four sets of forcibly
defined device numbers and
numeric data are displayed.
A maximum of four sets can be forcibly defined in mode 2. If four sets have been defined and
additional setting is made, forward feed is made and the subsequent four sets become effective.
key. The data is processed and forcibly defined.
INPUT
),
X0008 is displayed at the beginning and bit 0 changes to "1".
7.4 PLC Interface Diagnosis
[PLC-I/F]
<SET DATA>
76543210
HEX
X0000 oooooooo
00
X0008 ooooo1o1
04
X0010 oooooooo
00
X0018 o1o1oooo
50
DEVICE
DATA
MODE
( X8
) (
1 )
( 2)
ALARM
SERVO
SPINDLE
[PLC-I/F]
<SET DATA>
76543210
HEX
X0008 ooooo1o1
05
X0010 oooooooo
00
X0018 o1o1oooo
50
X0020 1o1ooo11
A3
I-272
7. Diagnosis
ALARM/DIAGN 4
76543210
HEX
D0005
oooooooo
o11oo1oo
D0006
1oooooo1
ooooo1oo
DEVICE
DATA
MODE
(
) (
)
( )
PLC-I/F
MENU
ALARM/DIAGN 4
X0008=0001
76543210
HEX
D0005
oooooooo
o11oo1oo
D0006
1oooooo1
ooooo1oo
00
64
81
04