Error Code
101-115
201-231
P
ARAMETER
PARAMETERS SHOULD BE ADJUSTED ONLY IF THE FUNCTION IS
OPERATING OUTSIDE OF MACHINE SPECIFICATIONS, OR IF WRITTEN
APPROVAL IS OBTAINED FROM MEC PRIOR TO MAKING THE CHANGE.
M
S
A I N
C R E E N
The following screen is displayed during normal machine operation at the Base
Controls station. Not all of the icons shown appear all of the time.
Troubleshooting
Machine Tilted Beyond Safe Limits Fault: If the machine is tilted, find a way to
62
make it level.
63
The platform has reached the Anti-hand pinch position
Left Brake Coil Fault: Check the connections to the Coil's terminals and make
64
sure they are tight. If so, check the coil itself to see if it is open or shorted.
Right Brake Coil Fault: Check the connections to the Coil's terminals and make
65
sure they are tight. If so, check the coil itself to see if it is open or shorted.
66
Charge battery
69
Restart the power
90
TM1 over current
91
TM1 over current
95
Turning the traction motor
99
Bypass was enabled by human
Contact MEC Customer Service or replace ECU