Mec Micro 19-XD Operator's Manual
Hide thumbs Also See for Micro 19-XD:

Advertisement

Operator's Manual
Micro 19-XD
Art_5588
Serial Number Range
Part # 43893
1610000 - Up
July 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Micro 19-XD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mec Micro 19-XD

  • Page 1 Operator’s Manual Micro 19-XD Art_5588 Serial Number Range Part # 43893 1610000 - Up July 2020...
  • Page 2 Added Safe Electrical Distances Chart For Safety Per A92.20-2018 July 2020 Updated To Include 2 Person Indoors With Xtra Deck Stowed Rating MEC Aerial Work Platforms 1401 S. Madera Avenue, Kerman, CA 93630 USA Toll Free: 1 - 877 - 632 - 5438...
  • Page 3: Table Of Contents

    July 2020 Table of Contents Section 1 - Introduction ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� Introducton ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������...
  • Page 4 July 2020 Section 12 - Warning and Instructional Decals ����� ����� ����� ����� ����� ����� ����� ����� ����� 34 Decal Locatons ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������ ������...
  • Page 5: Section 1 - Introduction

    Your MEC Aerial Work Platform has been designed, built, and tested to provide safe, dependable service. Only authorized, trained and qualified personnel shall be allowed to operate or service the machine.
  • Page 6: Section 2 - Safety

    For your safety and the safety of those around you, you must operate your machine as instructed in this manual. MEC designs aerial work platforms to safely and reliably position personnel, along with their necessary tools and materials, at overhead work locations. The owner/user/operator of the machine should not accept responsibility for the operation of the machine unless properly trained.
  • Page 7: Safety Alert Symbols & Fall ProtectOn

    Secton 2 - Safety July 2020 Safety Alert Symbols & Fall Protection MEC manuals and decals use symbols, colors and signal words to help you recognize important safety, operation and maintenance information. RED and the word DANGER – Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury�����...
  • Page 8: Section 3 - Machine Specifications

    Secton 3 - Machne Specfcatons July 2020 Machine Specifications Machine Specifications Indoor 24.4 ft 7.43 m Working Height* Outdoor 19 ft 5.79 m Indoor 18.4 ft 5.6 m Platform Height Outdoor 13 ft Indoor 18.4 ft 5.6 m Maximum Drive Height Outdoor Top Guardrail 83.3 in...
  • Page 9: Section 4 - Hazards

    Secton 4 - Hazards July 2020 Electrocution Hazard Electrocution Hazard ELECTROCUTION HAZARD! THIS MACHINE IS NOT INSULATED! DEATH OR SERIOUS INJURY will result from contact with or inadequate clearance from any electrically charged conductor����� You must maintain a CLEARANCE OF AT LEAST 10 FEET (3����� 0 5 m) between any part of the machine, or its load, and any electrical line or apparatus carrying over 300 Volts up to 50,000 Volts�����...
  • Page 10: MNMum Safe Approach DStance

    Secton 4 - Hazards July 2020 Minimum Safe Approach Distance 5000 V Max. volts Higher voltage 20000 V Min. volts 15000 V 10000 V Lower voltage 5000 V Min. volts (b) Avoid simultaneous contact across (a) Affected area areas of high potential difference CLEARANCES FROM LIVE AERIAL CONDUCTORS Spotter required...
  • Page 11 Secton 4 - Hazards July 2020 When working in the area of energized conductors the user shall direct and the operator shall comply with the requirements to: Stay at least 10 feet away from power lines with any part of their body, conductive object or any part of the MEWP.
  • Page 12: TP-Over Hazards

    NEVER replace any part of the machine with items of different weight or specification. Art_2831 NEVER modify or alter the work platform without written permission from MEC. NEVER place ladders or scaffolds in the platform or against any part of the machine.
  • Page 13: Fall & CollSOn Hazards

    Secton 4 - Hazards July 2020 Fall & Collision Hazards Fall Hazards DO NOT sit, stand or climb on the platform guard rails. Maintain a firm footing on the platform floor at all times. DO NOT sit, stand or climb on the platform guard rails. Maintain a firm footing on the platform floor at all times.
  • Page 14: AddTOnal Safety Hazards

    Secton 4 - Hazards July 2020 Additional Safety Hazards Explosion and Fire Hazards DO NOT operate the machine in hazardous locations or locations where potentially flammable or explosive gasses or particles may be present. Damaged Machine Hazards Conduct a thorough pre-start inspection of the machine and test all functions before each work shift to check for damage, malfunction and unauthorized modification.
  • Page 15: Xtra Deck Deployment And StowNg

    Secton 5 - Xtra Deck Instructons July 2020 Xtra Deck Deployment And Stowing Xtra Deck Deployment And Stowing Warning! Only 1 person is allowed on the machine when the Xtra Deck is deployed����� The preferred platform position to deploy or stow the Xtra Deck is with the slide-out deck extended. 1.
  • Page 16 Secton 5 - Xtra Deck Instructons July 2020 Important: Maximum capacity - 1 person - 250 lbs (113Kg) The control box may be placed on the upper telescopic guardrail and the machine controlled as instructed in this manual. 4. Fold up the Xtra Deck •...
  • Page 17: Section 6 - Folding Guardrails

    Secton 6 - Foldng Guardrals July 2020 Folding Guardrails Folding Guardrails Folding Guardrail Instructions The platform railing system consists of three fold down rail sections. Fully lower the machine, extend the platform extension, have the Xtra Deck stowed and the telescopic guardrails lowered.
  • Page 18 Secton 7 - Components and Controls July 2020 Component Locations Component Locations Xtra Deck Up Xtra Deck Down 1) Platform Controller 2) Platform Guard Rails 3) Platform Extension Release Pedal 4) Platform Entry Gate 5) Main Platform 6) Lift Cylinders 7) Entry Ladder 8) Drive Wheels 9) Emergency Lowering Knob...
  • Page 19: Platform Controls

    Secton 7 - Components and Controls July 2020 Platform Controls Art_5534 ALWAYS be aware of the machine’s position and of your surroundings before activating any control function����� Control Description Thumb Rocker Switch Press the thumb rocker switch in either direction to activate steer function. Drive Select Press this button to select the drive function.
  • Page 20: Lower Controls

    Secton 7 - Components and Controls July 2020 Lower Controls Art_5587 ALWAYS be aware of the machine’s position and of your surroundings before activating any control function����� Control Description Displays diagnostic codes when necessary. Hour Meter The hour meter displays the number of hours the machine has operated. Platform Lift / Lower With the Key Switch in the BASE position, move this switch up to lift the Switch...
  • Page 21: Section 8 - Workplace Inspection

    Secton 8 - Workplace Inspecton July 2020 Workplace Inspection Workplace Inspection DO NOT operate this machine until you have read and understood this manual, have performed the Workplace Inspection, Pre-Start Inspection and Routine Maintenance, and have completed all the test operations detailed in the Operating Instructions section����� Inspect the workplace and determine whether the workplace is suitable for safe machine operation.
  • Page 22: OperatNg InstructOns & FunctOns Test

    Secton 9 - Operatng Instructons and Functon Tests July 2020 Operating Instructions & Functions Test Operating Instructions & Functions Test DO NOT operate this machine until you have read and understood this manual, have performed the Workplace Inspection, Pre-Start Inspection and Routine Maintenance, and have completed all the test operations detailed in the Operating Instructions section.
  • Page 23 Secton 9 - Operatng Instructons and Functon Tests July 2020 Functions Test Select a test area that is firm, level and free of obstruction. Be sure the battery pack is connected. Turn the main power switch to ON (pulled out) position. At the Ground Controls Turn the ground red Emergency Stop button clockwise to the on position Pull out the platform red Emergency Stop button to the on position.
  • Page 24 Secton 9 - Operatng Instructons and Functon Tests July 2020 At the Platform Controls Turn the Key Switch to platform control. Test Emergency Stop Push in the platform red Emergency Stop button to the off position. • Result: No functions should operate. Turn the red Emergency Stop button clockwise to the on position.
  • Page 25 Secton 9 - Operatng Instructons and Functon Tests July 2020 Test Drive and Braking Press and hold the Function Enable Switch on the control handle. Slowly move the control handle in the direction indicated by the blue up arrow on the control panel until the machine begins to move, then return the handle to the center position.
  • Page 26 Secton 9 - Operatng Instructons and Functon Tests July 2020 Emergency Lowering If the control system fails while the platform is elevated, use the emergency lowering procedure to safely lower the platform����� Do not climb down the scissor assembly or exit the platform����� The Emergency Lowering System is used to lower the platform in case of power failure.
  • Page 27 Secton 9 - Operatng Instructons and Functon Tests July 2020 To Position Platform Move the up/down toggle switch according to the markings on the control panel. Art_5534 Art_5534 Operation from Platform Turn the Key Switch to platform control. Set the red Emergency Stop buttons to the ON position at both the ground and platform controls.
  • Page 28 Secton 9 - Operatng Instructons and Functon Tests July 2020 To Drive Press the drive function select button. Press and hold the Function Enable Switch on the control handle. • Increase speed: Slowly move the control handle off center. • Decrease speed: Slowly move the control handle toward center.
  • Page 29 Secton 9 - Operatng Instructons and Functon Tests July 2020 While holding the piece of wood level, measure the distance from the bottom of the piece of wood to the ground. Divide the tape measure distance (rise) by the length of the piece of wood (run) and multiply by 100. Example: •...
  • Page 30 Secton 9 - Operatng Instructons and Functon Tests July 2020 To Extend and Retract the Deck Extension Deck Extension Press the platform lock pin foot pedal on the extension deck. Release Pedal Push the platform extension guardrail to extend the platform to the desired position.
  • Page 31: Section 10 - Battery Charging

    Charge the battery in a well-ventilated area����� Use proper AC input voltage for charging as indicated on the machine����� Use only MEC authorized batteries and chargers����� IMPORTANT: Be sure to disconnect the charger from the outlet before attempting to operate the unit.
  • Page 32: Section 11 - Maintenance

    Secton 11 - Mantenance July 2020 Maintenance Maintenance DO NOT operate this machine until you have read and understood this manual, have performed the Workplace Inspection, Pre-Start Inspection and Routine Maintenance, and have completed all the test operations detailed in the Operating Instructions section����� The operator must conduct a Pre-Start Inspection of the machine and test all functions before each work shift to check for damage, malfunction and unauthorized modification.
  • Page 33 Secton 11 - Mantenance July 2020 Use only recommended lubricants����� Improper lubricants or incompatible lubricants may cause as much damage as no lubrication����� Watch for makeshift “fixes” which can jeopardize safety as well as lead to more costly repair����� Inspection and maintenance should be performed by qualified personnel familiar with the equipment�����...
  • Page 34: LubrCatOn

    Secton 11 - Mantenance July 2020 Lubrication Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must be performed by a qualified service technician. FULL Hydraulic Component Unit Tray ART_5000 No����� Item Specification Frequency Mobile Fluid DTE 10, DTE 13 M, or AW32 Routine Maintenance Check hydraulic oil level every week...
  • Page 35: Pre-Start InspectOn ChecklSt

    Secton 11 - Mantenance July 2020 Pre-Start Inspection Checklist The operator must conduct a Pre-Start Inspection of the machine before each work shift. DO NOT use a damaged or malfunctioning machine. Initial Description Be sure that the operator’s manual are complete, legible and in the storage container located in the platform.
  • Page 36: Frequent InspectOn ChecklSt

    Secton 11 - Mantenance July 2020 Frequent Inspection Checklist This checklist must be used at 3-month intervals or every 150 hours of machine use, whichever occurs first����� Failure to do so could result in death or serious injury����� Frequent Maintenance Inspections should be conducted by qualified service technicians only. Photocopy this page for reuse.
  • Page 37: Annual InspectOn Report

    Secton 11 - Mantenance July 2020 Annual Inspection Report Aerial Platform Sales Corp “Y” Yes/Acceptable “N” No/Unacceptable 1401 South Madera Avenue, Kerman, California 93630, USA “R” Repaired Tel: 559.842.1500 Toll Free: 1.877.632.5438 Fax: 559.842.1520 “U” Unnecessary/Not Applicable Email: info@MECawp.com Web: www.MECawp.com Date Customer Dealer...
  • Page 38 Secton 12 - Warnng and Instructonal Decals July 2020 Decal Locations Decal Locations 24 25 * Opposite side of Xtra Deck also * Opposite side of Xtra Deck also ** One on water diverter plate 20 21 24 25 31** ** On water diverter plate Page 34 Mcro 19-XD - Operator’s Manual...
  • Page 39 Secton 12 - Warnng and Instructonal Decals July 2020 95224 Qty. - 2 95208 Qty. - 2 41638 Qty. - 2 94362 Qty. - 4 95215 Qty. - 1 90732 Qty. - 2 42534 Qty. - 1 43910 Qty. - 1 94659 Qty.
  • Page 40 Decal, Tip-Over Hazard 94846 Decal, Micro 19 Brake Release Instructions 95301 Decal, Trademarked MEC Logo, Small (Black) 43886 Decal, 2020 ANSI Capacity - Micro 13-XD, Micro 19-XD 41635 Decal Instructions - Tie Down Point 41634 Decal Instructions - Lift Point 41649...
  • Page 41 Secton 12 - Warnng and Instructonal Decals July 2020 Serial Plate Serial Plate Location The serial plate is attached to the machine at the time of manufacture. Important information about the machine is recorded on the serial plate. ART_4999 Serial Plate Description MODEL NUMBER: Identifies the machine.
  • Page 42 • Obvious fluid leak or damaged component? • Wires disconnected, broken, or loose? • Diagnostic panel on? • Platform Control Box Fault Code present? Refer to service manual or contact MEC Technical Support. Page 38 Mcro 19-XD - Operator’s Manual...
  • Page 43 MEC machinery����� Truck drivers are responsible for loading and securing machines, and should be properly trained and authorized to operate MEC machinery����� Drivers are also responsible for selecting the correct and appropriate trailer according to government regulations and company policy����� Drivers must ensure that the vehicle and chains are strong enough to hold the weight of the machine (see the serial number plate for machine weight)�����...
  • Page 44 Secton 14 - Transport and Lftng Instructons July 2020 Resetting Brakes Press the Emergency Stop button, then push the Brake Release Switch to the right to reset the brake. Driving or Winching onto or off of a Transport Vehicle Always attach the machine to a winch when loading or unloading from a truck or trailer by driving�����...
  • Page 45 Secton 14 - Transport and Lftng Instructons July 2020 • Adjust the rigging to prevent damage to the chains and the machine. Ensure that angle of each hold-down chain or strap does not exceed 30° relative to the trailer deck����� Truck Tie Down Minimum 4 chains of adequate capacity MAXIMUM...
  • Page 46 MEC Parts Order Form Phone: 559-842-1523 Fax: 559-400-6723 Email: Parts@mecawp����� c om Please fill out completely Date: Ordered By: Account: Your Fax No.: Ship to: Bill to: Purchase Order Number Ship VIA ** All orders MUST have a Purchase Order Number...
  • Page 47 MEC Aerial Platform Sales Corp. and is found upon inspection by MEC Aerial Platform Sales Corp. to be defective in material and/or workmanship. MEC Aerial Platform Sales Corp. shall not be liable for any consequential, incidental or contingent damages whatsoever.
  • Page 48 MEC Aerial Work Platforms 1401 S. Madera Avenue, Kerman, CA 93630 USA Toll Free: 1 - 877 - 632 - 5438 Phone: 1 - 559 - 842 - 1500 Fax: 1 - 559 - 842 - 1520 info@MECawp.com www.MECawp.com...

This manual is also suitable for:

Micro 13-xd

Table of Contents

Save PDF