Terminal Module Tm54F - Siemens SIMOTION D425-2 Manual

Hide thumbs Also See for SIMOTION D425-2:
Table of Contents

Advertisement

Table 7-37
Type
Digital inputs
Digital inputs/outputs
Analog inputs
TTL encoder output
NOTICE
Overheating if ventilation clearances are too small
Insufficient ventilation clearances result in overheating and therefore in more failures and a
shortened life of the component.
Maintain 50 mm ventilation clearances above and below the component.
Additional references
You will find detailed information about the TM41 Terminal Module in the
7.8

Terminal Module TM54F

Characteristics of the TM54F
The TM54F Terminal Module is a terminal expansion module for snapping on to a DIN EN
60715 mounting rail. The TM54F offers safe digital inputs and outputs for control of Safety
Integrated functions of SINAMICS.
No more than one TM54F can be assigned to each drive control (SINAMICS Integrated of a
D4x5‑2, CX32‑2, CU320‑2, etc.). Connection is via DRIVE‑CLiQ. Each drive control must have
its own dedicated TM54F.
TM54 is equipped with the following terminals:
Table 7-38
Type
Fail-safe digital outputs (F‑DO)
Fail-safe digital inputs (F‑DI)
Sensor
supported
Sensor
Digital inputs for testing the F‑DO during test stop 4
SIMOTION D4x5-2
Manual, 04/2014
Interface overview
SINAMICS S120 Control Units and Additional System Components Manual
SIMOTION D4x5-2 Commissioning and Hardware Installation Manual.
Interface overview
power supplies, dynamic response
1)
2)
power supplies, no dynamic response
1)
Supplementary system components
7.8 Terminal Module TM54F
Quantity
4
4
1
1
Quantity
4
10
2
1
131