Component
TM120 Terminal Module
Terminal Module TM150
SMx Sensor Modules
Motors with DRIVE‑CLiQ interface ... allow simplified commissioning and diagnostics, as the motor
DMC20/DME20 DRIVE‑CLiQ hub ... enables the number of DRIVE‑CLiQ interfaces to be increased
Note
You will find detailed information on components in the SINAMICS S110/S120 family of
products in the SINAMICS S110/S120 manuals.
It is possible that older DRIVE‑CLiQ components can no longer be used with SIMOTION
D4x5‑2/CX32‑2. You will find detailed information on this in SIMOTION D4x5-2
Commissioning and Hardware Installation Manual at "Migration of D4x5 to D4x5‑2" in Section
"Permissible combinations."
Optional components
The functionality of the D4x5‑2 control unit can be expanded with the following components:
Table 2-7
Component
CBE30-2 Ethernet
communication board
TB30 Terminal Board
The components are plugged into the option slot of the control unit.
SIMOTION D4x5-2
Manual, 04/2014
Function
4 temperature sensors (KTY84‑130 or PTC) can be evaluated via
the TM120 Terminal Module. The temperature sensor inputs are
safely electrically separated from the evaluation electronics in the
TM120 Temperature Module and are suitable for evaluating the
temperature of special motors, e.g. 1FN linear motors and 1FW6
built-in torque motors.
The TM150 Terminal Module can be used to evaluate temperature
sensors (KTY, PT100, PT1000, PTC, and bimetal normally closed
contact). This means, for example, that other temperatures from
the process can be measured in addition to the motor temperature.
Temperature sensors can be evaluated using a 2, 3 or 4‑wire
system. 12 temperature sensors can be evaluated with 2‑wire
evaluation and 6 temperature sensors with 3 and 4‑wire
evaluation.
... enable acquisition of encoder data from connected motors via
DRIVE‑CLiQ.
and encoder type are identified automatically.
and the creation of a point-to-point topology.
Optional components
Function
Communication via PROFINET IO with
IRT and PROFINET IO with RT
Terminal expansion, i.e. additional
analog and digital I/Os
Description
2.2 System components
D4x5-2 DP
D4x5-2 DP/PN
No
Yes
Yes
Yes