Supplementary system components
7.3 TB30 terminal board
7.3.3.6
Working with analog inputs
The following reference contains more information about analog inputs:
● /IH1/
● /GH1/
7.3.3.7
Commissioning
Information about commissioning can be found in the
Hardware Installation Manual.
7.3.4
Technical Specifications
Power supply of digital outputs
Table 7-10
Characteristic
Power supply
Response time
108
SINAMICS S120 Commissioning Manual.
SINAMICS S120 Control Units and Additional System Components Manual
Terminal block X424
Value/Range
Voltage: 24 VDC (20.4 V – 28.8 V)
Current via the option slot of the D4x5‑2 (without digital outputs): 0.05 A
Max. power consumption: 4 A
Max. power consumption per digital output: 0.5 A
Power loss: < 3 W
The response time of digital inputs/outputs and analog inputs/outputs
depends on the evaluation on the control unit (see function diagram).
References: SINAMICS S120/S150 List Manual, Chapter "Function
diagrams"
SIMOTION D4x5-2 Commissioning and
SIMOTION D4x5-2
Manual, 04/2014