Interfaces

4.2 DRIVE-CLiQ interfaces

Interface
2. USB interface
Option slot
Note
The third port of the PROFINET X150 P3 IO interface has an additional caption for a
SIMOTION D4x5-2 DP/PN. It is called X120 PN/IE-OP.
This designation is not relevant for SIMOTION D.
Non-usable interfaces
Table 4-2
Interface name
RS232 interface
4.2
DRIVE-CLiQ interfaces
DRIVE-CLiQ interfaces
All SINAMICS S120 drive system components, including the motors and encoders, are
interconnected by a shared serial interface called DRIVE-CLiQ. The standardized cables and
connectors reduce the variety of different parts and cut storage costs.
DRIVE-CLiQ has the following properties:
● Automatic detection of components by the Control Unit
● Standardized interfaces to all components
● Uniform diagnostics down to the components
● Complete service down to the components
● 24 V / 450 mA per DRIVE‑CLiQ interface are provided for the connection of encoders and
52
Overview of interfaces that cannot be used for SIMOTION D
measuring systems.
Note:
The DRIVE‑CLiQ cable with 24 V supply is used only for components that require this (e.g.
motors with a DRIVE‑CLiQ interface).
Designation
X135
Interface
X140
Connector type
USB socket
Sockets
Connector type
9-pin Sub-D connector