Supplementary system components

7.4 CBE30-2 Ethernet communication board

7.4
CBE30-2 Ethernet communication board
7.4.1

Overview

Properties of the CBE30‑2
A second PROFINET interface can be implemented for the SIMOTION D4x5-2 DP/PN with
the CBE30-2 Ethernet communication board.
The CBE30-2 cannot be used with the SIMOTION D4x5-2 DP.
The CBE30-2 offers the following functions:
● PROFINET IO controller, I device (also controller and device simultaneously)
● 100 Mbps full duplex / autocrossing
● Supports real-time classes of PROFINET IO:
The CBE30‑2 has an X1400 interface with an integral 4-port switch based on PROFINET
ASICs ERTEC400.
View
The connections and LED displays are located on the front of the CBE30‑2.
Figure 7-7
110
– RT (real-time)
– IRT (isochronous real-time)
CBE30‑2 front view