● Digital inputs (DI)
● Bidirectional digital inputs/outputs (DI/DO)
Bidirectional digital I/Os can be configured individually as digital inputs or outputs.
Assignment of the I/Os to functions can be parameterized as required. Special functions (e.g.
input of the measuring input) can be assigned to the I/Os.
The digital inputs/outputs on the X122 front connector can be used by either SIMOTION or
SINAMICS (e.g. as enable signal for a drive).
Table 7-24
Galvanic isolation
Use as:
● Freely addressable I/Os
● I/Os that are assigned to
● Measuring inputs
● Inputs for the external
● Cam outputs
Configuration:
Assignment
Note
For optimal noise immunity of the digital inputs, the use of shielded cables is necessary in
certain cases. This is necessary when the digital inputs are to be used as
● Inputs of measuring inputs or
● Inputs for the external zero mark
Additional references
For information on configuring the I/Os as freely addressable I/Os or as measuring inputs, see
the
For information on the configuration and function of the measuring input, output cam, and cam
track technology objects, see the
Manual.
SIMOTION D4x5-2
Manual, 04/2014
Use of the digital inputs/outputs
for SIMOTION
the drive
zero mark
SIMOTION D4x5‑2 Commissioning and Hardware Installation Manual.
DI 0-3, DI 16, DI 17 (X122)
Electrically isolated
(ground reference M1)
yes
yes
no
no
no
Can be configured channel-by-
channel on the drive
SIMOTION Output Cams and Measuring Inputs Function
Supplementary system components
7.5 CX32-2 controller extension
DI/DO 8-11 (X122)
Non-isolated
(ground reference M)
yes
yes
Yes
(global and local measuring inputs)
yes
no
Can be configured channel-by-
channel on the drive