4.4 Digital I/Os

4.4
Digital I/Os
4.4.1

Properties

Interface characteristics
The digital I/Os on the X122, X132 and X142 connectors are for the connection of sensors
and actuators.
Table 4-7
Features
Connector type
Connectable cable types and conductor cross-
sections
Stripped length
Tool
Max. cable length
Max. current carrying capacity (ground)
58
Wiring of X122, X132 and X142
Rigid
Flexible
Flexible, with wire-end ferrule without plastic
sleeve
Flexible, with wire-end ferrule with plastic
sleeve
AWG / kcmil
Type
14-way spring-loaded terminal
0.2 mm² ... 1.5 mm²
0.2 mm² ... 1.5 mm²
0.25 mm² ... 1.5 mm²
0.25 mm² ... 0.75 mm²
24 ... 16
10 mm
Screwdriver 0.4 x 2.0 mm
30 m
6 A