Technical data of the D4x5-2

5.5 Interfaces and performance features

Note
If the D4x5‑2 detects undervoltage, the module performs a RESET. If all LEDs are off, either
there is no power supply or the voltage level is too low.
When the voltage level is in the permissible range again, the D4x5‑2 restarts.
Undervoltages are detected when:
● The voltage level of the 24-V supply falls below the minimum permissible input voltage of
● A temporary voltage dip (> 3 ms) results in the supply falling below the minimum
Additional references
Recommended power supply units and tables for calculating the current consumption for the
assembly with SINAMICS S120 modules can be found in the "Control cabinet installation and
EMC booksize" chapter in the
5.5
Interfaces and performance features
Memory for system data
Table 5-9
Data
Diagnostic buffer
(non-volatile)
RAM (working
memory)
RAM disk (load
memory)
Retentive memory
Persistent memory
(user data on CF)
1)
82
the D4x5-2
permissible input voltage on the D4x5‑2.
Memory for system data and its memory size
Memory size
D425-2
200 messages
(SIMOTION)
200 messages
(SINAMICS
Integrated)
48 MB
1)
31 MB
364 KB
1-GB CF: 300
MB
A separate 20 MB of working memory is available for Java applications.
SINAMICS S120 Booksize Power Units Manual.
Memory size
D435-2
200 messages
(SIMOTION)
200 messages
(SINAMICS
Integrated)
64 MB
41 MB
364 KB
1-GB CF: 300 MB
Memory size
Memory size
D445-2 DP/PN
D455‑2 DP/PN
200 messages
200 messages
(SIMOTION)
(SIMOTION)
200 messages
200 messages
(SINAMICS
(SINAMICS
Integrated)
Integrated)
128 MB
256 MB
56 MB (as of V4.3)
76 MB (as of V4.3)
50 MB
50 MB
512 KB
512 KB
1-GB CF: 300 MB
1-GB CF: 300 MB
SIMOTION D4x5-2
Manual, 04/2014