Interface assignment for X126
Table 4-17
Pin
1
2
3
4
5
6
7
SIMOTION D4x5-2
Manual, 04/2014
The position of the PROFIBUS X126 and X136 interfaces (example of SIMOTION D4x5‑2
DP/PN)
SIMOTION D4x5‑2 Commissioning and Hardware Installation Manual, Section
Connecting PROFIBUS DP
PROFIBUS DP interface X126
Signal name
Signal type
--
--
M
VO
1RS_DP
B
1RTS_DP
O
1M
VO
1P5
VO
P24_SERV
VO
Meaning
Reserved, do not use
Ground to P24_SERV
RS-485 differential signal
Request to send
Ground to 1P5
5 V power supply for bus terminal, external, short-circuit proof
24 V for teleservice, short-circuit proof, 150 mA maximum