Supplementary system components

7.11 DMC20 DRIVE-CLiQ hub

Interface
Encoder interface (HTL, TTL, SSI)
Only SSI encoders without incremental tracks may be
operated.
DRIVE-CLiQ cable length, max.
1)
NOTICE
Overheating if ventilation clearances are too small
Insufficient ventilation clearances result in overheating and therefore in more failures and a
shortened life of the component.
Maintain 50 mm ventilation clearances above and below the component. The ventilation
openings may not be covered by connecting cables.
Additional references
You will find more information on the CUA31/CUA32 control unit adapter in the
SINAMICS S120 AC Drive Manual.
7.11
DMC20 DRIVE-CLiQ hub
Properties
The DMC20 and DME20 DRIVE‑CLiQ hub modules are used to implement point-to-point
distribution of a DRIVE‑CLiQ line. With the DMC20/DME20, an axis grouping can be expanded
with four DRIVE‑CLiQ sockets for additional subgroups.
● DMC20 is the hub for the control cabinet configuration
● DME20 is the hub for use without a control cabinet (IP67 degree of protection).
The modules are especially suitable for applications which require DRIVE‑CLiQ nodes to be
removed in groups, without interrupting the DRIVE‑CLiQ line and therefore the data exchange.
Additional references
You will find detailed information about the DMC20/DME20 in the following source:
SINAMICS S120 Control Units and Supplementary System Components Manual
134
CUA31 with order number 6SL3040-0PA00-0AAx (x ≥ 1 required)
CUA31
CUA32
1)
0
1
100 m
100 m
SIMOTION D4x5-2