Starting The Engine Of The Tractor; Ignition System Disorders Signalization - Zetor FORTERRA HSX 100 2014 Operator's Manual

Table of Contents

Advertisement

STARTING THE ENGINE OF THE
TRACTOR
As a standard, the tractors are equipped
by glow plugs in the heads of rollers.
When starting the engine, it is
necessary to sit on the driver´s
seat.
1. Insert the key to the switchbox ("0"
position).
2. Depress the clutch pedal.
3. Shift the main gear shifting lever to
neutral position.
4. Shift the reversing lever to neutral po-
sition.
5. Make sure that all PTO switches on
the right column of the cabin are
switched off.
DRIVING OPERATION
FH12N051
6. Turn the key to "I" position. A yellow
control will light up on the dashboard
signalising the proper igniting function.
7. Wait for the ignition control to turn off
(the time is dependent on the temper-
ature of the coolant).
If the ignition control merely
blinks instead of lighting up, there
is a disorder in the ignition sys-
tem (see ch.: Ignition system dis-
order signalization). The signal-
ised fault must be resolved in an
expert service garage.
8. Turn the key to the "II" position (start).
9. After starting the engine, release the
key immediately. Do not start for more
than 15 sec.
FH112N052
IGNITION SYSTEM DISORDERS
SIGNALIZATION
Ignition system disorders are signalized
by blinking of ignition control.
- If ignition control blinks at standstill
- If the ignition control blinks at standstill
- If the ignition control blinks permanently
64
once per second, ignition in emergen-
cy system occurs just like at low tem-
peratures regardless of the tempera-
ture of coolant.
twice per second, the ignition is put off
operation (does not work).
during the run of engine, there is a dis-
order of ignition control and ignition has
not been completed. The disorder must
be forthwith removed, because there is
the danger of battery depletion.