Air Filter With Active Carbon - Zetor FORTERRA HSX 100 2014 Operator's Manual

Table of Contents

Advertisement

*AIR FILTER WITH ACTIVE CARBON

Active carbon filters are installed in the placed of standard dust filter and the re-
placement is done in the same way as with standard filters. Filter must be inserted
with the white side to the grid. Assembly instructions are found in the chapter
"Maintenance instructions".
Filter is used only when spraying pesticides, then it must be replaced back by a paper
filter because the flying dust would clog the carbon filter very fast.
The recirculation control must be in the position "air is sucked from the outside"
Ventilator control must be in the position "maximum ventilator run"
 WARNING: filter does not provide full protection against toxic substances
 Wear protective gloves when manipulating with the filter
 Do not clean the filter and do not blow through with compressed air
DANGER: Replace the active carbon filter every 200 hours or 36 months (date
of production is given on the filter). If you happen to smell pesticides in the
cabin, replace the filter immediately and have the sealing of the cabin
checked. Used filters must be damaged in specialized collection centres
ACQUAINTANCE WITH THE TRACTOR
F13BN015
37
When spraying pesticides and
using heating filters with active
carbon, the recirculation control
must be in the position of „air
sucked from the outside" and the
ventilator control "maximum venti-
lator run" for creating surplus
pressure in the cabin