Parameter unit (FR-PU07), parameter unit with battery pack (FR-PU07BB(-L))

3.2
Parameter unit (FR-PU07),
parameter unit with battery pack (FR-PU07BB(-L))
Parameter setting and monitor display can be performed by connecting the parameter unit (FR-PU07) or the parameter unit
with battery pack (FR-PU07BB(-L)) to the converter. Note that their functions are limited compared to when they are used
with the inverter. PU represents both a parameter unit and an operation panel (FR-DU07-CNV) in some sections of this
manual.
 Batteries are not included in FR-PU07BB-L.
3.2.1

Parts identification of the parameter unit

POWER lamp
Lit when the power turns ON.
Monitor
Liquid crystal display
I In
10.0
(16 characters
A
STF FWD PU
backlight)
Interactive parameter setting
Help function
Trouble shooting guidance
Monitor (current, power, etc.)
ALARM lamp
Lit to indicate an inverter
alarm occurrence.
Operation keys
FR-PU07
3.2.2

Explanation of keys

Key
Used to select the parameter setting mode.
Press to select the parameter setting mode.
Used to display the first priority screen.
Used to display the input frequency when making an initial setting.
Operation cancel key.
Used to display the function menu.
A variety of functions can be used on the function menu.
Used to shift to the next item in the setting or monitoring mode.
Used to enter a parameter number or set value.
to
Cancels the
Does not function
 Press either of these keys on the parameter setting mode screen to change the parameter setting value
sequentially.
/
 On the selecting screen, these keys are used to move the cursor.
 Hold down
Does not function
Does not function
 Stop command key.
 Used to reset the converter when a fault occurs.
 Used to write a set value in the setting mode.
 Used as a clear key in the all parameter clear or fault history clear mode.
 Used as a decimal point when entering numerical value.
 Used as a parameter number read key in the setting mode.
 Used as an item select key on the menu screen such as parameter list or monitoring list.
 Used as an fault definition display key in the fault history display mode.
 Used as a command voltage read key in the calibration mode.
NOTE
 Do not use a sharp-pointed tool to push the keys.
 Do not press your fingers against the liquid crystal display.
4 lines with
Description
(PS) display when the converter is stopped by the
and press either of these keys to advance or return the display screen one page.
POWER lamp
Lit when the power turns ON.
Battery exhaustion warning lamp
When a battery is low, the lamp color
changes from green to orange.
I In
10.0
Monitor
A
STF FWD PU
Liquid crystal display
(16 characters
Interactive parameter setting
Help function
Trouble shooting guidance
Monitor (current, power, etc.)
ALARM lamp
Lit to indicate an inverter
fault occurrence.
Operation keys
FR-PU07BB
(PU stop).
4 lines with backlight)
69
3